The Flurocyl
2
solar cylinder is available in three sizes: 200, 250,
and 300 litres. The containers are made from stainless steel with
EPS insulation. The cylinder is supplied along with all required
cold and hot water control devices and a 2-way motorised valve.
The cylinder works with the pressure of the water supply line
and does not need a cold water tank for its supply. The cylinder
has hot and cold water connections with a diameter of 22 mm.
To enable the cylinder to work as well as possible, a cold water
supply with an appropriate pressure and flow rate is required.
9.1.1
Cylinder operating elements
5
4
1
2
7
8
3
6
Key
1 Cover cap for reset button for reheating circuit TCO
2 Reheating circuit temperature controller
3 electric immersion heater cover
4 Cover cap for reset button for solar circuit TCO
5 solar circuit safety thermostat (TCO)
6 electric immersion heater
7 Cylinder thermostat
8 Reheating circuit safety thermostat
The following are pre-mounted at the factory for the Flurocyl
2
solar cylinder:
Cylinder thermostat (7) and reheating circuit safety thermostat (8)
Electric immersion heater (6) with safety thermostat and cylinder
thermostat
Solar circuit safety thermostat (5)
The cylinder must be properly wired in order to comply with G3
building regulations.
You must connect the solar pump to the solar
controller via the solar circuit safety thermostat.
The thermostat switches the solar pump off if the
temperature of the hot water in the cylinder exceeds
80 °C.
9.1.2
electric immersion heater operating elements
1
2
3
4
5
1
2
3
Key
1 electric immersion heater temperature controller
2 electric immersion heater TCO reset button
3 electric immersion heater
The cylinder is equipped with an additional electric immersion
heater (3) with a heating output of 3 kW. The electric immersion
heater is located behind the top front cladding. The electric
immersion heater is designed for use in unvented cylinders and
has a thermostat with a temperature controller (2) and a safety
thermostat (TCO) with a reset button (1).
If you need to make a replacement, you must use
the correct electric immersion heater with a safety
thermostat for overheating protection. Only use
original replacement parts from Glow-worm. Always
replace the immersion heater gasket when parts are
replaced.