Technical data, 6 technical data – Glow-worm Clearly Solar Cylinders User Manual
Page 10
![background image](/manuals/736748/10/background.png)
0020115479_03 - 10/12 - Glow-worm
- 8 -
TECHNICAL DATA
TeCHNICal DaTa
6 Technical data
Unit
Flurocyl
2
200
Flurocyl
2
250
Flurocyl
2
300
Total capacity
l
200
250
300
Actual capacity
l
209.4
254.4
297.2
Hot water capacity (upper coil)
l
104.8
142
144.2
Hot water capacity (solar coil)
l
203.3
246.1
271.1
Dedicated solar volume
l
104.6
112.4
153.0
Maximum supply pressure to pressure reducing valve
bar
12
Maximum operating pressure of cylinder
bar
7
Maximum operating pressure of heating coil
bar
3.5
Maximum operating pressure of solar coil
bar
6
Operating pressure
bar
3.5
Pressure limiting valve
bar
3.5
Expansion relief valve
bar
6.0
Temperature and pressure relief valve
bar
7.0
Charge pressure of hot water expansion vessel
bar
4.0
Maximum temperature of heating circuit
oC
85
Maximum temperature of potable hot water
oC
85
Maximum temperature of solar fluid
oC
85
Standing heat loss
kW/24h
2.05
2.20
2.40
Heat up time according to EN 12897
mins
22
29
30
Recovery time (70% capacity)
mins
16
21
22
Primary heat exchanger performance
kW
14.9
15.3
15.0
Flow rate for primary heat exchanger performance
l/min
23.3
23.3
23.3
Primary heat exchanger pressure drop
mbar
79
78
79
Primary heat exchanger volume
l
2.37
2.37
2.37
Primary heat exchanger surface area
m2
0.5
0.5
0.5
Solar heat exchanger performance
kW
18.7
18.5
16.5
Flow rate for solar heat exchanger performance
l/min
23.3
23.3
23.3
Solar heat exchanger pressure drop
mbar
97
95
98
Solar heat exchanger volume
l
2.94
2.94
2.94
Solar heat exchanger surface area
m2
0.62
0.62
0.62
Heat up time according to EN12897 (solar)
mins
34
42
51
Temperature and pressure relief valve
oC/bar
90 / 7.0
Dimensions
Height
mm
1593
1843
2153
Height with hot water draw off
mm
1625
1875
2185
Topple measure
mm
1680
1918
2217
Diameter
mm
554.5
Depth
mm
624
Net weight
kg
40
43
50
Weight (filled)
kg
249
298
347
Connections
Cold water inlet
22mm compression joint
Hot water draw-off
22mm compression joint
Balanced pressure cold water outlet
22mm compression joint
Secondary return
15 mm compression joint