3 Installation

3.1 Contents of sets

Using Table1, verify the contents of the Fluropro solar control

set.

Item

Quantity Components

1

1

Fluropro

2

1

Collector sensor

3

2

Cylinder sensor

Table 1

The gain sensor is a separate item and is also supplied as

part of the Glow-worm Clearly Sets.

3.2 Installing cylinder sensors

The cylinder sensors are designed so that they can be used

as immersion sensors or surface sensors.

Install the two sensors in the solar cylinder, see diagram 3.1,

and connect to the wiring as shown in wiring diagram.

When used as a surface sensor, the sensor is secured to

the flow pipe or the return pipe as appropriate using the

supplied tension band, see diagram 3.2. In order to guarantee

good heat transfer, the sensor is flat on one side. We also

recommend that the pipe with the sensor is insulated, in order

to enable the best possible measuring of temperature.

Refer to cylinder instructions for the location of sensors and

specific fitting instructions.

3.3 Accessories

If a second collector array is connected, it is necessary

to install a second collector sensor from the Glow-worm

accessory range.

3.4 Installing the Fluropro housing

The Fluropro solar control is designed to be mounted on

a wall. The wiring terminals within this control includes the

connectors. These connectors must be used for all wiring to

this control.

The cover consists of two parts, which can be removed

separately:

• As shown in diagram 3.3, pull the lower front cover off of the

controller housing.

• Mark the position of both holes and drill, see diagram 3.4.

• Select wall plugs to suit, and screw the controller housing on

tightly.

14261

Diagram 3.2

14260

Diagram 3.3

14361

Diagram 3.1

UPPER

TEMPERATURE

SENSOR

LOWER

TEMPERATURE

SENSOR

TEMPERATURE

SENSOR

GAIN