3 Installation
3.1 Contents of sets
Using Table1, verify the contents of the Fluropro solar control
set.
Item
Quantity Components
1
1
Fluropro
2
1
Collector sensor
3
2
Cylinder sensor
Table 1
The gain sensor is a separate item and is also supplied as
part of the Glow-worm Clearly Sets.
3.2 Installing cylinder sensors
The cylinder sensors are designed so that they can be used
as immersion sensors or surface sensors.
Install the two sensors in the solar cylinder, see diagram 3.1,
and connect to the wiring as shown in wiring diagram.
When used as a surface sensor, the sensor is secured to
the flow pipe or the return pipe as appropriate using the
supplied tension band, see diagram 3.2. In order to guarantee
good heat transfer, the sensor is flat on one side. We also
recommend that the pipe with the sensor is insulated, in order
to enable the best possible measuring of temperature.
Refer to cylinder instructions for the location of sensors and
specific fitting instructions.
3.3 Accessories
If a second collector array is connected, it is necessary
to install a second collector sensor from the Glow-worm
accessory range.
3.4 Installing the Fluropro housing
The Fluropro solar control is designed to be mounted on
a wall. The wiring terminals within this control includes the
connectors. These connectors must be used for all wiring to
this control.
The cover consists of two parts, which can be removed
separately:
• As shown in diagram 3.3, pull the lower front cover off of the
controller housing.
• Mark the position of both holes and drill, see diagram 3.4.
• Select wall plugs to suit, and screw the controller housing on
tightly.
14261
Diagram 3.2
14260
Diagram 3.3
14361
Diagram 3.1
UPPER
TEMPERATURE
SENSOR
LOWER
TEMPERATURE
SENSOR
TEMPERATURE
SENSOR
GAIN