Regulations
When installing and commissioning the system, the current
version of regulations below shall be observed.
The electrical installation must be installed by a
competent
person and in accordance with the relevant standards
Electrical Supply
The product MUST be earthed.
All system components shall be of an approved type and all
wiring to current I.E.E. wiring regulations.
External wiring must be correctly earthed, polarised and in
accordance with the relevant standards.
In GB, this is BS 7671.
In IE, this is the current edition of ETCI rules.
The product MUST be connected to a permanent 230V ac,
50Hz supply.
Connection of the whole electrical system of the product,
including any heating controls, to the electrical supply MUST
be through one common isolator and must be fused 3 Amp
maximum.
Isolation should be by a double pole switched fused spur box,
with a minimum gap of 3mm for both poles. The fused spur
box should be readily accessible and preferably adjacent to
the product. It should be identified as to its use.
Alternatively connection can be made through an unswitched
shuttered socket and 3A fused 3-pin plug both to the current
issue of BS 1363, provided they are not used in a room
containing a bath or shower.
Wiring to the product must be PVC 85°C insulated cable, not
less than 0.75mm2 (24/0.20mm).
Testing and Certification
This product is tested and certificated for safety and
performance. It is, therefore, important that no alteration is
made to the product, without permission, in writing, by Glow-
worm.
Any alteration not approved by Glow-worm, could invalidate
the certification, warranty and may also infringe the current
issue of the statutory requirements.
WARNINGS
SAFETY
The fluropro must be installed by a competent person, who is responsible for adhering to
the existing standards and regulations.
ALTERATIONS
Under no circumstances should you ever attempt to make alterations to these
components or any other part of the system
SEALED COMPONENTS
Under no circumstances must the user interfere with or adjust sealed parts.
IMPORTANT
Danger of death by electric shock! All live parts of the system may be installed, serviced and repaired
only by a qualified servicing company!
Risk of overvoltage! Earth the solar circuit as potential equalisation and protection against
overvoltage! Attach earthing pipe clips to the solar circuit pipes and connect the clips to a potential
rail with a 16mm
2
copper cable.
CE Mark
The CE mark on the Fluropro solar control indicates that
it complies with the basic requirements of the applicable
directives as stated on the data badge.
“Benchmark scheme”
Glow-worm support the Benchmark initiative. It is very
important that the service record is completed by the
installation engineer and handed over to the user.
Safety Instructions
The entire solar system must always be installed and
operated in accordance with recognised technical standards.
IMPORTANT: Danger of death by electric shock! All live parts
of the system may be installed, serviced and repaired only by
a qualified servicing company!
IMPORTANT: Risk of overvoltage! Earth the solar circuit as
potential equalisation and protection against overvoltage!
Attach earthing pipe clips to the solar circuit pipes and
connect the clips to a potential rail with a 16mm
2
copper cable.