Technical data, 6 envirosorb – Glow-worm Clearly Heat Pumps 14kW User Manual
Page 12

0020117819_01 - 05/11 - Glow-worm
- 10 -
TECHNICAL DATA
i
This technical data is valid for a new appliance with its
own heat exchangers.
6 Envirosorb
Description
Unit
7
12
14
Min. operating outside temperature (in heating)
°C
-20
-20
-20
Max. operating outside temperature (in heating)
°C
30
30
30
Specifi cations, with radiators
(fl ow : 45°C, return : 40°C, outside dry temperature (wet) 7 (6)°C)
Heating output
kW
7.4
12.95
14
Power input
kW
2.34
4.3
4.36
Rated electrical current
A
10
18.7
19
COP* A7(6) W45-40
3.16
3.01
3.21
Specifi cations, with underfl oor heating
(fl ow : 35°C, return : 30°C, outside dry temperature (wet) : 7 (6)°C)
Heating output
kW
7.2
11.9
14.5
Power input
kW
1.84
3.04
3.57
Rated electrical current
A
8
13.2
15.6
COP* A7(6) W35-30
3.91
3.91
4.06
Refrigerant circuit
Type of refrigerant
Quantity of refrigerant
kg
1.81
2.485
3.385
Type of compressor
Rotary
Type of oil
Polyolester
Type of regulator
Electronic
Fan speed
rpm
1000
805
1050
Maximum operating pressure (PS)
bar
45
45
45
Pa
45 x 10
5
45 x 10
5
45 x 10
5
Heat pump circuit
Max. supply pressure.
bar
3
3
3
Pa
3 x 10
5
3 x 10
5
3 x 10
5
Min. supply pressure
bar
0.5
0.5
0.5
Pa
50 x 10
3
50 x 10
3
50 x 10
3
Nominal water fl ow rate in heating mode
l/h
1200
2100
2500
Flow rate detection threshold
l/h
500
500
500
Min. volume of the installation
l
28
42
49
Max volume of heat pump circuit, without auxiliary tank, for a water outlet
temperature of 35°C
l
65
95
95
Minimum fl ow temperature setting (in heating)
°C
20
20
20
Maximum fl ow temperature setting (in heating)
°C
60
60
60
Volume of water in the heat pump
l
1.2
2.3
2.3
TECHNICAL DATA