39
A Technical Specifications
I
MPORTANT
The following technical specifications can change without notice.
The information presented in this section is provided as a reference
only. To obtain this product’s most recent technical specifications,
visit the EXFO Web site at www.exfo.com.
Specifications
a
FTTx MODE
PPM-352C PPM-353C
Power measurement range—pass zone for continuous data stream (dBm)
1310 nm
8 to –40
8 to –40
1490 nm
12 to –40
12 to –40
1550 nm
25 to –40
N/A
Burst measurement capability
CO to ONT
CO to ONT
Burst measurement range
b
(dBm)
1310 nm
8 to –30
8 to –30
ORL
e
(dB)
1550
nm
55
55
Pass-through insertion loss
b
(dB)
1.5
1.5
Spectral passband (nm)
1310 nm
1260 to 1360
1260 to 1360
1490 nm
1480 to 1500
1480 to 1500
1550 nm
1539 to 1565
1539 to 1565
Power uncertainty
b, c, d
(dB)
0.5
0.5
Calibrated wavelengths (nm)
1310/1490/1550
1310/1490
Threshold sets
10 configurable threshold sets
10 configurable threshold sets
with threshold naming
with threshold naming
GENERAL SPECIFICATIONS
Size (H x W x D)
195 mm x 100 mm x 57 mm ( 7
11
/
16
in x 4 in x 2
1
/
4
in)
Weight
f
0.4 kg (0.9 lb)
Temperature
Operating
–10 °C to 50 °C (14 °F to 122 °F)
Storage
f
–40 °C to 70 °C (–40 °F to 158 °F)
Relative humidity
0 % to 95 % non-condensing
Autonomy
b
(hours)
FTTx
mode
(burst)
35
OPM mode (CW)
80
Number of ports
2
Warranty and recommended calibration interval (years)
g
3
Notes
a. At room temperature.
b. Typical.
c. Around –7 dBm, CW.
d. At calibrated wavelengths.
e. For APC connectors.
f. Without batteries.
g. Excluding connector wear.