0 specifications and troubleshooting tips, 0 accessories parts – ENMET RECON Series User Manual
Page 13

R
ECON
ENMET Corporation
11
6.0 Specifications and Troubleshooting Tips
6.1 Specifications
Electrical Power
Working Voltage
3.6
V
DC
Lithium battery,1200 mAh Rechargeable
Working time continuous, non-alarm conditions
Combustible gas: Approximately 8 hours
Toxic gas: Approximately 30+ hours
Charge time
4 to 6 hours
Operation
Temperature:
–20
°
C to +50
°
C
Relative Humidity
5 to 95% RH, non-condensing
Mechanical
Dimensions:
2.4 x 3.9 x 1.3 inches(60 x 100 x 33 mm)
Weight:
5 oz. (140g) including battery
Ingress Protection
IP 65
Approval
Designed to be intrinsically safe
N
OTE
:
All specifications stated in this manual may change without notice.
6.2 Troubleshooting Tips
M
ALFUNCTION
P
OSSIBLE
R
EASONS
S
OLUTIONS
Unable to Turn on the detector
low voltage
Charge Battery
Detector Fault
Contact ENMET Corporation
Circuit malfunction
Contact ENMET Corporation
No reaction to the tested gas
Exhausted Sensor
Replace Sensor
Circuit malfunction
Contact ENMET Corporation
Inaccurate indication
Exhausted sensor
Replace the sensor
Overdue Calibration
Calibrate
Wrong time display
Exhausted battery
Charge and reset the time
Electromagnetic disturb
Reset the time
Zero calibration function failed
Too much drift
Calibrate or replace the sensor
7.0 Accessories Parts
Recon is supplied with a belt clip(4) and an alligator-type clip(1) with a D-ring(2). These can be attached to the instrument as
shown below.
010101Belt Clip & Alligator
Type Clip Attached
Alligator-Type Clip
2.
D-Ring
1.
Alligator-Type Clip
4.
Belt Clip
Attached
3.
Fastening Screw