Replacing the Fuses

Warning

To avoid electrical shock or damage to the meter, only use
replacement fuses

5x20 0.5A/250V FAST or

6x25

10A/250V FAST.

Referring to Figure 19, examine or replace the meter’s fuses as
follows:

1. Turn the Function Rotary Switch to the OFF position and remove

the test leads from the terminals.

2. Remove the holster from the meter. Then, using a screwdriver,

unscrew the two screws on the back case and remove it.

3. Remove either fuse by gently prying one end loose, then sliding

the fuse out of its bracket.

4. Install ONLY the specified replacement fuses with the amperage,

voltage, and speed ratings:

5x20 0.5A/250V FAST or

6x25

10A/250V FAST.

5. Reinstall the back case. Secure the back case by turning the

screws clockwise.

Figure 19. Fuse Replacement

-32-

!

Screw

∅6x25 10A/250V FAST
Elenco

®

part # 531101

∅5x20 0.5A/250V FAST
Elenco

®

part # 533004