CPD 3000 Integration Guide
7
Wiring Specification and Diagram
Here are the wiring specifications and diagram for US and European models of the
CPD 3000. The CPD 3000 is not suitable for installing above 15,000 feet altitude.
The controller must be installed in the light fixture, inside a street light pole, or in a
street light cabinet. The CPD 3000 is not intended to be installed in an open
outdoor environment.
US Model
Three AWG 16 wires for AC mains input:
Black Line
In
White
Neutral In or Line 2 In*
Green Ground
*
May be powered Line-to-Line if Line-to-Line Voltage is 100-277 VAC and all CPD 3000s, and the
segment controller, are connected to the same circuit pair.
Three AWG 22 wires for control of signal ouput (IEC60929)
Blue
10V signal for PWM control
Black Ground
Violet
Signal for 0-10V control
European Model
Three AWG 16 wires for AC mains input:
Brown Line
In
Blue
Neutral In or Line 2 In*
Green/Yellow Ground
*
May be powered Line-to-Line if Line-to-Line Voltage is 100-277 VAC and all CPD 3000s, and the
segment controller, are connected to the same circuit pair.
Three AWG 22 wires for control of signal ouput (IEC60929)
Blue
10V signal for PWM control
Black
+ Signal for 0-10V control
White
- Signal for 0-10V control