Unvtcontrolcfg – Echelon Lumewave CPD 3000 Lighting Controller User Manual
Page 15
![background image](/manuals/735714/15/background.png)
CPD 3000 Integration Guide
15
nciPowerProfile UNVTpowerProfile
Defines the nominal power
measured at 5 commanded
nviLampValues
0.5%, 25%,
50%, 75%, 100%) while driving
the driver/lamp combination.
This CP must be set for
lowPower/HighPower, and
measured with nvoLampFb
values to work correctly. They
will depend on the minPWM and
maxPWM
fields defined in the
following section.
UNVTControlCfg
This section describes how the fields in this configuration property are applied in the
LC.
Figure 5
. UNVTcontrolConfig Field Details
Field
Type
Notes
defaultLev SNVT_lev_cont
This is the initial value before an update
to nviLampValue is received by the LC to
drive the lamp value at power ON or reset.
The default value is 100%. This value only
applies after the CPD 3000 is commission
by the SmartServer. When unconfigured,
the CPD 3000 will turn ON the controlled
light to full ON. When power is applied to
the OLC, the application enforces a 10s
minimum time (even if CoolDownTm =0)
before applying this value. A non-zero