Jt9 operator’s manual – Ditch Witch JT9 User Manual
Page 153
Service - 152
JT9 Operator’s
Manual
As Needed
CMW
®
Change Hydraulic Filter (Anytime
System Opened)
Change hydraulic filter anytime system is opened
for repair. Change filter and refill with THF at
hydraulic oil fill.
Check Track Tension and Condition
Check track tension and condition, and adjust or
replace as needed. See your Ditch Witch
®
dealer
for replacement parts.
To adjust
1.
Pump MPG into fitting (A) until the length of the
compressed spring, dimension (B), is 15.25”
(387.35 mm).
2.
Drive straight forward one machine length and
check tension again.
IMPORTANT: If hydraulic system must be
opened for repair, install new filter (p/n 153-791)
for first 50 hours of operation. If this filter
becomes plugged in fewer than 20 hours,
replace with new filter. After 50 hours of normal
operation, replace with new filter (p/n 153-792).
Tier 4i
Tier 4
- JT5 (161 pages)
- JT922 (159 pages)
- JT20 (195 pages)
- JT1220 (201 pages)
- JT2020 (203 pages)
- JT25 (203 pages)
- JT30 (245 pages)
- JT60 (218 pages)
- JT100 (243 pages)
- AT Air Hammer (11 pages)
- TK Series Manual (61 pages)
- 8500 (77 pages)
- MR90 (121 pages)
- FT5 (28 pages)
- FM5 (57 pages)
- FM13V (46 pages)
- FM25 (67 pages)
- P80 (71 pages)
- OnGrade (63 pages)
- FX20 (100 pages)
- FX25 (119 pages)
- FX30 (149 pages)
- FX50 (141 pages)
- FX60 (157 pages)
- MV800 (111 pages)
- RT Line (115 pages)
- RT30 (97 pages)
- RT45 (203 pages)
- RT55 (177 pages)
- RT100 (161 pages)
- RT115 (252 pages)
- RT120 (223 pages)
- Zahn (105 pages)
- RT80 (203 pages)
- RT115 Q (193 pages)
- RT120 Q (211 pages)
- 100SX (50 pages)
- 410SX (131 pages)
- SK350 (77 pages)
- SK750/SK755 (81 pages)
- SK850 (107 pages)
- SK850 Footings Machine (107 pages)
- 150RT (55 pages)
- 250RT (49 pages)