Jt922 operator’s manual – Ditch Witch JT922 User Manual
Page 140
JT922 Operator’s
Manual
Service - 139
50 Hour
CMW
Check and Adjust Engine Belt Tension
Check belt tension every 50 hours. Belt is properly
tensioned when it moves about 3/8” (10 mm) when
pushed at the long span (A).
To adjust belt, move tensioner pulley:
1.
Loosen socket bolt (2) and bolt (1).
2.
Use a prybar in slots (3) to move pulley.
3.
Tighten socket bolt (2) and bolt (1).
4.
Check tension.
Clean Alternator Cooler Turbine
Clean the alternator cooler turbine every 50 hours.
Remove side panel and use compressed air to
blow dirt and debris from fins (shown).
Note: Boltheads are hidden. Use an 8 mm hex
wrench, 17 mm open end wrench, and a 1/2”
prybar for this procedure.
See also other documents in the category Ditch Witch Special machinery:
- JT5 (161 pages)
- JT9 (165 pages)
- JT20 (195 pages)
- JT1220 (201 pages)
- JT2020 (203 pages)
- JT25 (203 pages)
- JT30 (245 pages)
- JT60 (218 pages)
- JT100 (243 pages)
- AT Air Hammer (11 pages)
- TK Series Manual (61 pages)
- 8500 (77 pages)
- MR90 (121 pages)
- FT5 (28 pages)
- FM5 (57 pages)
- FM13V (46 pages)
- FM25 (67 pages)
- P80 (71 pages)
- OnGrade (63 pages)
- FX20 (100 pages)
- FX25 (119 pages)
- FX30 (149 pages)
- FX50 (141 pages)
- FX60 (157 pages)
- MV800 (111 pages)
- RT Line (115 pages)
- RT30 (97 pages)
- RT45 (203 pages)
- RT55 (177 pages)
- RT100 (161 pages)
- RT115 (252 pages)
- RT120 (223 pages)
- Zahn (105 pages)
- RT80 (203 pages)
- RT115 Q (193 pages)
- RT120 Q (211 pages)
- 100SX (50 pages)
- 410SX (131 pages)
- SK350 (77 pages)
- SK750/SK755 (81 pages)
- SK850 (107 pages)
- SK850 Footings Machine (107 pages)
- 150RT (55 pages)
- 250RT (49 pages)