Checking the signal – rf remote control only, Changing the code – Bonaire Reverse Cycle User Manual
Page 32

Multi-Appliance Comfort Control
Page 32
Controls- Installation / Setup / Commissioning
1. Turn the main switch ON to the unit. If the power has already been applied, turn the main switch OFF,
then ON again.
2. Press the ▲ arrow and the ON/OFF button for 5 seconds until the word “CODE” flashes.
3. Code flashes for 15 seconds. When code stops flashing the unit is now ready to turn on.
C
HECKING
T
HE
S
IGNAL
–
RF
R
EMOTE
C
ONTROL
O
NLY
There are 3 ways you can check if the wall control is communicating
with unit control board.
1. The red light on the indoor unit control board will flicker when
receiving a signal.
2. The transmission symbol on the control will show for a flash
only. If the symbol hangs for approximately 2 seconds there is
no transmission.
3. Press the MANUAL/AUTO and CLEAN FILTER/ZONE ABCD
for 15 seconds.
•
If the 2 dots between the hours and the minutes flash
together signal OK. If the 2 dots alternate there is no
communication.
•
Press ENTER in each location to check the signal.
•
The test function stays active for 5 minutes after the
last time ENTER is pressed. Where there is no signal,
try re-coding the unit.
C
HANGING THE
C
ODE
It is possible for the Code (digital address) to be duplicated in another installation nearby which will
interfere with the successful operation of your unit. To change the code:
1. Turn the system main switch OFF, then ON.
2. Press the HEAT/COOL/FRESH AIR button and the ON/OFF button for 5 seconds until the words
SET CODE and 4 digits show.
3. Each digit can be altered using the ▼ or ▲ buttons. Press ENTER for each digit or digit change.
When all digits have been changed the word CODE will appear briefly until the update has taken
place.
There is a 4 minute window in which to code the unit. Code flashes for 15 seconds. When code stops
flashing the unit is now ready to turn on.