Assembly, Operating temperature range – Bonaire Reverse Cycle User Manual
Page 13
![background image](/manuals/734422/13/background.png)
Multi-Appliance Comfort Control
Page 13
Ducted Reverse Cycle
A
SSEMBLY
There is no assembly required of this Ducted Reverse Cycle Air Conditioner. Your Dealer or installer will
carry out all assembly and commissioning upon installation.
O
PERATING
T
EMPERATURE
R
ANGE
Although the controller will allow the operating set temperature to be adjusted between 5 to 36°C, it is
important that the controller settings be maintained within the following temperature ranges:
o
Heating
Only
Mode 16
to
27°C
o
Cooling Only Mode
18 to 32°C
o
Heating & Cooling Mode
18 to 27°C
The Bonaire air conditioner has been designed for the following temperatures. The operation of the Bonaire
air conditioner must be within this operational temperature ranges below.
Cooling
Temperature (°C)
Indoor
18 to 32
15 to 23
Outdoor
DB
5 to 43
WB
-
Heating
Temperature (°C)
Indoor 16
to
27 -
Outdoor
DB
-5 to 25
WB
-6 to 18
If the system is used when the temperatures are outside the operating ranges above, safety devices may
activate causing the system to stop.
If the system is used on heating below the minimum temperature ranges above, the outdoor heat
exchanger may freeze and cause the unit to malfunction and stop. If the system is to be installed in
locations where the ambient temperature falls below the minimum operating ranges stated above,
supplementary BOOST heating may be required (contact your dealer for advice on this option).