beautypg.com

Connection examples: en, Drv drive dr v – Bimba OLE User Manual

Page 14

background image

Connecting another drive to EN

(When output closes, input closes)

Connecting an NPN Type Proximity Sensor to an input

(When prox sensor activates, input closes)

STR

EN-

EN+

Si drive

OUT+

OUT–

5-24

VDC

Power

Supply

-

+

STR

NPN

Proximity

Sensor

EN-

EN+

output

+

12-24

VDC

Power

Supply

-

+

Connecting a PNP Type Proximity Sensor to an input

(When prox sensor activates, input closes)

STR

PNP

Proximity

Sensor

EN+

output

+

EN-

12-24

VDC

Power

Supply

-

+

Connecting an Input to a Switch or Relay

STR

switch or relay

(closed=logic low)

EN-

EN+

5-24

VDC

Power

Supply

-

+

Connection Examples: EN

DRV

DRV

DRV

DRIVE

DR

V

The 5-24 V EN input disables power to the motor.