beautypg.com

Bimba OLE User Manual

Page 10

background image

e. Adjust running and idle current

d. Set rotary switch for the motor selected

(This is normally set by the factory for the motor specified.)

Switch 1 and 2 set the running

current to 70%, 80%, 90%

or 100% of the motor’s

rated maximum current.

1 2

100%

1 2

90%

1 2

80%

1 2

70%

4

50%

4

90%

Switch 4 sets the idle current

to either 50% or 90% of the

selected running current.

Factory default is 90%.

OLE

Bimba Motor

Frame

Option Code

Setting

-75

17 frame

P1, E1, Y1, Z1

5

-75

23 frame

P2, E2, Y2, Z2

7

-150

23 frame

P2, E2, Y2, Z2

6

-350

34 frame

P3, E3, Y3, Z3

F

• Use 100% position in most ap-

plications (factory default)

• Use lower settings for self lock-

ing threads (OLE 12, 16, and

20 leads).

• Use lower settings to reduce

motor temperature

• Use higher settings for full hold-

ing torque

Turn the rotary switch to the number that represents

the motor you have. This sets current and anti-

resonance settings for optimum performance.

8

!

• Use lower setting during

initial setup to avert

accidental damage

• Use lower settings to address

safety issues

• Use lower settings to reduce

motor temperature