AMT Datasouth M7 User Manual
Page 70
Page of 73
70
Adjust the print head pressure adjustment knob
The print head pressure adjustment knob has 5 levels of settings.
Clockwise direction adjustment is to increase the print head
pressure. Counter Clockwise adjustment can decrease the print
head pressure. If the wrinkle on the label starts from the lower left
side to upper right side, please do following adjustment.
1. Decrease the right side print head pressure adjustment knob
setting 1 level per each adjustment then print the label again to
check if wrinkle is gone.
2. If the right side print head adjustment knob setting has been set
to index 1 (the lowest pressure index), please increase the left side
print head pressure.
3. If the left side print head adjustment knob setting has been set to
5 (the highest pressure index) the wrinkle can’t be avoid, please
rotate the both knobs back to setting 1 then rotate the Z-axis
mechanism adjustment knob clockwise for a few degrees and print
again for fine tune the print head pressure distribution.
Note for step 3:
*Factory default setting, the Z-axis knob is rotated counter clockwise
to the end of thread.
*Turn the Z-axis mechanism adjustment knob clockwise until you
feel the knob touch the mechanism for the first adjustment.
* If the wrinkle is still there, please turn the Z-axis mechanism
adjustment knob clockwise about 1/4 circle each time for adjustment
* If the winkled direction is change from " " to " " by adjusting the
Z-axis mechanism adjustment knob, please turn the Z axis
mechanism adjustment knob counter clockwise to avoid the wrinkle.
Adjust the print head pressure adjustment
knob
The print head pressure adjustment knob
has 5 levels of settings. Clockwise
Direction adjustment is to increase the
print head pressure. Counter Clockwise
adjustment can decrease the print head
pressure. If the wrinkle on the label starts
from the lower right side to upper left
side, please do following adjustment.
1. Decrease the left side print head
pressure adjustment knob setting 1 level
per each adjustment then print the label
again to check if wrinkle is gone.
2. If the left side print head adjustment
knob level has been set to index 1 (the
lowest index), please increase the right
side print head pressure.
Right knob
Left knob
Right knob
Left knob
Z axis mechanism
adjustment knob