Warranty – Advanced Control Technologies Specs Instructions ZDP100 (RF CONTROLLED, 300W, 120 VAC,PLUG-IN LAMP MODULE) User Manual
Page 7

ZDP100 Instructions, Release 2.0
090805
HomePro
by ADVANCED CONTROL TECHNOLOGIES, INC.
0677-01
7
Power
120 VAC, 60 Hz
Signal (Frequency)
908.42 MHz
Maximum Load
300 W, for incandescent lamps only
Range
Up to 100 feet line of sight between the Wireless Controller and /or the
closest HomePro plug-In Lamp Module or Appliance Module
lamp wattage doesn’t exceed the 300W rating of the ZDP100. If a properly sized load is restored to the dimmer,
it can be operated normally once again.
Over-current protection
The ZDP100 hardware has an over current detection circuit, which is final protection against overload. If the
software fuse should fail to shut down the dimmer when overloaded, backup protection is provided by an internal
fuse. This fuse is not user serviceable. Check your home circuit breakers before concluding that the product must
be returned to manufacturer for repair at a nominal charge.
WARRANTY
For warranty and general product information visit our web site at www.act-solutions.com
FCC NOTICE
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions may cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interfer-
ence to radio or television reception, which can be determined by turning the equipment off and on, the user is encour-
aged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
IC NOTICE
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
About ZDP100’s Certification
The ZDP100 has been thoroughly tested by the ETL SEMCO division
of Intertek, a nationally recognized testing laboratory. This product
was found to be in compliance with safety standards ANSI/UL STD
244A and CAN/CSA C22.2 No. 177-92.
In addition to compliance with product safety standards, the
ZDP100 is also certified to comply with applicable FCC and IC
rules and regulations governing RF and EMI emissions.