System management > flags, System management > power up, System management > lvds backlight – ADLINK Express-BE User Manual
Page 51: System management > smart fan, System date and time, Advanced
Express-BE
Page 51
7.2.3.5.
System Management > Flags
Feature
Options
Description
Flags Info
only
BMC
Flags
Read
only
BIOS Select
Read only
Display the selection of current BIOS ROM
ATX/AT-Mode Read
only
Display
ATX/AT-Mode
Exception Code
Read only
System exception reason
7.2.3.6.
System Management > Power Up
Feature
Options
Description
Power Up
Info only
Power Up watchdog
Attention: F12 disables the Power Up
Watchdog.
Enabled
Disabled
The Power-Up Watchdog resets the system after a certain
amount of time after power-up.
ECO
Mode
Disabled
Enable
Reduces the power consumption of the system
Power-up
Mode
Attention: The Power-Up Mode only has
effect, if the module is in ATX-Mode.
Turn on
Remain off
Last State
Turn On: The machine starts automatically when the power
supply is turned on.
Remain Off: To start the machine the power button has to be
pressed.
Last State: When powered on during a power failure the system
will automatically power on when power is restored.
7.2.3.7.
System Management > LVDS Backlight
Feature
Options
Description
LVDS Backlight
Info only
LVDS Backlight Bright
255
The value range starts at 0 and ends at 255.
7.2.3.8.
System Management > Smart Fan
Feature
Options
Description
Smart Fan
Info only
CPU Smart FanTemperature
Source
CPU Sensor
System Sensor
Select CPU smart fan source
CPU Fan Mode
AUTO (Smart Fan)
Fan Off
Fan On
Select CPU fan mode
CPU Trigger Point 1
Read only
Trigger Temperature
15
Specifies the temperature threshold at which the BMC turns on
the CPU fan with the specified PWM level
PWM Level
30
Select PWM level
CPU Trigger Point 2
Read only
Trigger Temperature
60
Specifies the temperature threshold at which the BMC turns on