beautypg.com

Operation theorem • 35, Figure 4.2.9 stop mode i, Figure 4.2.10 stop mode ii – ADLINK PXI-2502 User Manual

Page 43: Figure 4.2.11 stop mode iii

background image

Operation Theorem

• 35

(UC _Counter=4, IC_Counter disabled)

4 update counts, infinite iterations

DAWR

WFG_in_progress

Operation start

Trigger

Output Waveform

0

2

4

stop trigger

Figure 4.2.9 Stop mode I

(Assuming the data in the data buffer are 2V, 4V, 2V, 0V)

(UC _Counter=4, IC_Counter disabled)

4 update counts, infinite iterations

DAWR

WFG_in_progress

Operation start

Trigger

Output Waveform

0

2

4

stop trigger

Figure 4.2.10 Stop mode II

(UC _Counter=4, IC_Counter=3, Trig_Counter>1)

4 update counts, finite iterations

DAWR

WFG_in_progress

Operation start

Trigger

Output Waveform

0

2

4

stop trigger

Figure 4.2.11 Stop mode III

This manual is related to the following products: