32 • operation theoreym, Figure 4.2.5 delay-trigger generation – ADLINK PXI-2502 User Manual

Page 40

background image

32

• Operation Theoreym

(UC _Counter=8, IC_Counter=1)

8 update counts, 1 iteration

DAWR

WFG_in_progress

Operation start

Trigger

Output Waveform

Delay until
DLY1_counter
reaches 0

Figure 4.2.5 Delay-Trigger Generation

(UC _Counter=4, IC_Counter=2, Trig_Counter=3 ,
DLY2_Counter disabled, DLY2_Counter disabled )

4 update counts, 2 iterations

Ignored

DAWR

WFG_in_progress

Operation start

Trigger

Output Waveform

0

2

4

a single waveform

Figure 4.2.6 Post-Trigger with Retrigger Generation

4.2.2.3 Iterative Waveform Generation

Users can set IC_counter to generate iterative waveforms, no matter which
Trigger Mode is used. The IC_counter stores the iteration number. Ex-
amples are shown in Figure 4.2.7 and 4.2.8.

When IC_counter is disabled, the waveform generation will not stop until a
stop trigger is asserted. For Stop Mode, please refer to Section 4.2.2.4 for
details.

An on-board data FIFO is used to buffer the waveform patterns for wave-
form generation. If the size of a single waveform is smaller than that of the
FIFO, after initially loading the data from the host PC’s memory, the data in
FIFO will be re-used when a single waveform generation is completed. In
other words, it won’t occupy the PCI bandwidth afterwards. However, if the

This manual is related to the following products: