3 specifications, Specifications – ADLINK PXI-2006 User Manual
Page 14

4
Introduction
1.3 Specifications
Analog Input (AI)
X
Number of channels: 4 differential
X
A/D converter:
Z
2010: LTC1414 or equivalent
Z
2005: A/D7665 or equivalent
Z
2006: A/D7663 or equivalent
Z
2016: A/D7671 or equivalent
X
Max sampling rate:
Z
2010: 2MS/s
Z
2016: 800kS/s
Z
2005: 500kS/s
Z
2006: 250kS/s
X
Resolution:
Z
2010: 14 bits, no missing code
Z
2005/2006/2016:16 bits, no missing code
X
FIFO buffer size:
Z
2010:8K samples
Z
2005/2006/2016: 512 samples
X
Programmable input range:
Z
Bipolar:
±
10V,
±
5V,
±
2.5V,
±
1.25V
Z
Unipolar: 0~10V, 0~5V, 0~2.5V, 0~1.25V
X
Operational common mode voltage range:
±
11V
X
Overvoltage protection:
Z
Power on: continuous
±
30V
Z
Power off: continuous
±
15V
X
Input impedance: 1G
Ω
/100pF