3xLOGIC VISIX Camera User Manual
Page 58
![background image](/manuals/732793/58/background.png)
USER MANUAL | VISIX 360 Network Camera
58
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
Record Parameters
!
Pre-‐record:
The
time
you
set
to
start
recording
before
the
scheduled
time
or
the
event.
For
example,
if
an
alarm
triggers
recording
at
10:00,
and
the
pre-‐record
time
is
set
as
5
seconds,
the
camera
starts
to
record
at
9:59:55.
The Pre-‐record time can be configured as No Pre-‐record, 5 s, 10 s, 15 s, 20 s, 25 s, 30 s or not limited.
!
Post-‐record:
The
time
you
set
to
stop
recording
after
the
scheduled
time
or
the
event.
For
example,
if
an
alarm
triggered
recording
ends
at
11:00,
and
the
post-‐record
time
is
set
as
5
seconds,
the
camera
records
until
11:00:05.
The Post-‐record time can be configured as 5 s, 10 s, 30 s, 1 min, 2 min, 5 min or 10 min.
Note:
The record parameter configurations vary depending on the camera model.
4) Click Edit to edit the record schedule.
Record Schedule
5) Choose the day to set the record schedule.
a) Set all-‐day record or segment record:
!
If you want to configure the all-‐day recording, please check the All Day checkbox.