Get/send buttons – Datalogic Scanning C-BOX 200 User Manual
Page 23
INSTALLATION
2
2.7.1 GET/SEND
Buttons
The C-BOX 200 has two internal function buttons (GET, SEND).
C-BOX 200
GET SEND
Figure 15 – Internal Function Buttons
The procedure to enable the GET/SEND function is the following:
1. Press both the GET and SEND buttons at the same time for at least one second;
the warning LED will turn ON.
2. Release the buttons.
3. Press the left button corresponding to the GET function or the right button
corresponding to the SEND function.
GET
–
(left button): the C-BOX 200 reads the current scanner configuration
and permanently copies it in its own memory support (EEPROM). The
C-BOX 200 preserves this configuration also when switched off.
SEND
-
(right button): the C-BOX 200 sends the configuration previously stored
in its own permanent memory support to the scanner’s EEPROM.
NOTE
Once the buttons are released in step 1, a ten-second timeout starts.
If no button is pressed within this time (no function is selected), the
procedure will be cancelled.
The C-Box 200 warning LED will turn OFF at the end of each
procedure.
15