Pin internal connector, 5 9-pin internal connector – Datalogic Scanning C-BOX 200 User Manual
Page 21
INSTALLATION
2
They are used together and they have the following significance:
when a jumper is in the J1 position (see Figure above) pin 40 is connected to pin 27
(EXT TRIG+); a jumper in J2 position connects pin 20 to pin 28 (EXT TRIG-).
If the jumpers are removed pin 20 and pin 40 are disconnected.
2.5 9-PIN INTERNAL CONNECTOR
The scanner auxiliary serial interface available on the internal 9-pin connector can be
used either for configuration through WinHost or for data monitoring.
The details of the connector pins are indicated in the following table:
Figure 14 - 9-pin male connector
9-pin connector pinout
Pin Name
Function
1
N.C.
2 RXA
Auxiliary
RS232
3 TXA
Auxiliary
RS232
4
N.C.
5 SGND
Signal
Ground
6
N.C.
9
N.C.
DS2100A - DS2400A
7
CTSA
Auxiliary Handshake RS232
8 RTSA
Auxiliary Handshake RS232
DS4600A
7
SGND AUX
Auxiliary Signal Ground
8 GND
Ground
13