beautypg.com

Aiphone TB-3F User Manual

Page 7

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

EXAMPLE NO. 3: TB-F SYSTEM WITH 2 DOOR STATIONS AND
ELECTRIC DOOR RELEASE

• Maximum of 2 door stations may be connected to up to 12 phones per system.
NOTES: (1) DB-U door station adaptor must be connected directly to PS-12A (PS-12C) power supply.

(2) Be sure to connect and [P] terminals on each phone for communication with door station

(paging may be added in a system incorporating door station).

(3) Do not use #1 terminal on any TB-F phone for connecting CF terminal on DB-U.

In this example button #5 allows conversation with door station #(T), button #6, with door
station #(2) and each station number button operates door release.

DOOR STATION

PS-12A or
PS-12C
Power Supply

* PLEASE SELECT THE MOST SUITABLE DOOR STATION FOR YOUR APPLICATION;

IC-DC

i

IC-NA

I

IC-RA

IC-KA

IC-JA

IC-FY

EXAMPLE NO. 4: TB-F SYSTEM WITH EXTERNAL SIGNALING DEVICE

1) When TB-F phone is located in very noisy area (station No. 7 in this example), an incoming call may be extended

by external signaling device such as bell or buzzer using RY-AC.

2) External signaling device (not supplied by Aiphone) should not exceed 0.3A 240V AC or l.OA 24V DC.

EXTERNALSIGNALING DEVICE

Power Supply

This manual is related to the following products: