Rs485 full-duplex interface, 2 rs485 full-duplex interface – Datalogic Scanning Compact 2D Reader Matrix-2000 User Manual
Page 57

19-PIN CONNECTOR ELECTRICAL CONNECTIONS
5
5.5.2 RS485
Full-Duplex
Interface
The RS485 full-duplex (5 wires + shield) interface is used for non-polled communication
protocols in point-to-point connections over longer distances (max 1200 m / 3940 ft) than
those acceptable for RS232 communications or in electrically noisy environments.
The following pins of the 25-pin connector are used for RS485 full-duplex communication:
Pin Name
Function
2
TX+
RS485 Transmit Data (+)
4
TX-
RS485 Transmit Data (-)
3
RX+
RS485 Receive Data (+)
5
RX-
RS485 Receive Data (-)
7
GND_ISO
Main opto-isolated reference ground
MATRIX
GND_ISO
RX+
RX-
TX-
TX+
USER INTERFACE
TX485
RX485
SHIELD
Reference Ground
7
3
5
4
2
+
1
-
+
-
Earth Ground
Earth Ground
Chassis
Figure 67 - RS485 Full-duplex Connections
NOTE
For applications that do not use RX485 signals, do not leave these lines
floating but connect them to GND_ISO as shown below.
MATRIX
GND_ISO
RX+
RX-
TX-
TX+
USER INTERFACE
RX485
SHIELD
Reference Ground
7
3
5
4
2
+
1
-
Earth Ground
Earth Ground
Chassis
Figure 68 - RS485 Full-duplex Connections using Only TX Signals
47