Power supply, Main serial interface, Rs232 interface – Datalogic Scanning Compact 2D Reader Matrix-2000 User Manual
Page 55: 4 power supply, 5 main serial interface, 1 rs232 interface

19-PIN CONNECTOR ELECTRICAL CONNECTIONS
5
5.4 POWER SUPPLY
Power is supplied to the reader through the pins provided on the 25-pin connector (see
Figure 64):
MATRIX
9/13
23/25
Vdc
GND
1
SHIELD
USER INTERFACE
CHASSIS
V- (Ground)
V+ (10 - 30 Vdc)
Earth Ground
Earth Ground
Chassis
Figure 64 - Power Supply Connection
The allowed supply voltage range is 10 to 30 Vdc.
5.5 MAIN SERIAL INTERFACE
The signals relative to the following serial interface types are available on the 25-pin
connector.
The main serial interface type and its parameters (baud rate, data bits, etc.) can be
defined by the user via VisiSet™ software. The RS485 half duplex is automatically set
whenever MUX32 communication protocol is enabled. For more details refer to the
"Communication" folder in the VisiSet™ Help On Line.
Details regarding the connections and use of the interfaces are given in the next paragraphs.
5.5.1 RS232
Interface
The opto-isolated RS232 interface can be used for Point-to-Point, Pass Through or
Master/Slave connections. When it is connected to the host computer it allows both
transmission of code data and reader configuration by VisiSet™.
The following pins of the 25-pin connector are used for RS232 interface connection:
Pin Name
Function
2 TX
Transmit
Data
3 RX
Receive
Data
4
RTS
Request To Send
5
CTS
Clear To Send
7
GND_ISO
Main opto-isolated reference ground
It is always advisable to use shielded cables. The overall maximum cable length must be
less than 15 m (49.2 ft).
45