Matrix-2000™ Reference Manual

1

CBX100/CBX500 Pinout for Matrix-2000™


The table below gives the pinout of the CBX100/CBX500 terminal block connectors. Use this
pinout when the Matrix-2000™ reader is connected by means of the CBX100/CBX500:

CBX100/500 Terminal Block Connectors

Input Power

Outputs

Vdc

Power Supply Input Voltage +

+V

Power Source - Outputs

GND

Power Supply Input Voltage -

-V

Power Reference - Outputs

Earth

Protection Earth Ground

O1+

Output 1 +

O1-

Output 1 -

Inputs

O2+

Output 2 +

+V

Power Source – External Trigger

O2-

Output 2 -

I1A

External Trigger A (polarity insensitive)

O3A

Output 3 +

(CBX500 only – polarity sensitive)

I1B

External Trigger B (polarity insensitive)

O3B

Output 3 -

(CBX500 only – polarity sensitive)

-V

Power Reference – External Trigger

Auxiliary Interface

+V

Power Source – Inputs

TX

Auxiliary Interface TX

I2A

Input 2 A (polarity insensitive)

RX

Auxiliary Interface RX

I2B

Input 2 B (polarity insensitive)

SGND

Auxiliary Interface Reference

-V

Power Reference – Inputs

Shield

Shield

Network Cable Shield

Main Interface

RS232

RS485 Full-Duplex

RS485 Half-Duplex

TX

TX+

RTX+

RTS

TX-

RTX-

RX

*RX+

CTS

*RX-

SGND

SGND

SGND


* Do not leave floating, see par. 4.2.2 for connection details.

CAUTION

Do not connect GND and SGND to different (external) ground references.
GND and SGND are internally connected through filtering circuitry which
can be permanently damaged if subjected to voltage drops over 0.8 Vdc.



CAUTION

If Matrix-2000™ is connected to a CBX with a BM100 Backup Module, then
the Matrix-2000™ 9-pin Auxiliary port connector cannot be used for
communication (i.e. configuration through VisiSet™). In this case use the
Auxiliary port 9-pin connector inside the CBX.