Mounting, Operations of mk-1sd/b, J technical precautions – Aiphone MK-1SD/B User Manual
Page 2: Specifications, Aiphone, Technical precautions
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
![background image](/manuals/726250/2/background.png)
WIRING DIAGRAMS
1. MK-1MD/A system
rSna : PS-18YC/A
or
PS-18YE
Red {+), Black (-), or
PS-18ME.
1 ~ 4 : Calling & communication
5: Door strike
Impedance-matching switch:
A
on MK-1MD/A.
2. KAS-1ED system
3H
O
MK-1SD/B
IER-2
2
To either
station
or both
At
A2
AC trans.
_
PT-1210N jaUkVI-B
At
A2
NP
MOUNTING
1. Attach the mounting bracket
to 1-gang box or wall.
2. Mount MK-1SD/B on the
bracket, aligning at the
marks. PulIMK-ISD/B
downward until it properly
locks.
.
Sinqle-ganq
Mounting t)ox
bracket
Screw(2)
supplied
OPERATIONS of MK-1SD/B
Receiving a cali from door station
When cali button is pushed on door station, it activates 4-tone chime
on main monitor station (with image) and MK-1SD/B sub. Lift
MK-1SD/B handset, if not answered by main monitor station. Call-in
times out in 30 seconds. Even after 30 seconds, pick up MK-1SD/B
handset to reply. The communication will be on for 2-1/2 minutes. To
allow entry, press and hold down Key-marked button to activate door
strike.
• Main monitor station and MK-1SD/B cannot call each other. Hang
up handset when the other station has answered the door station.
• In standby mode, lifting MK-1SD/B handset will connect with door
station.
J
TECHNICAL PRECAUTIONS----------
• Temperature:
MK-1SD/B is rated to operate at temperatures
between 0°C ~ 40°C (32°F - 104°F).
• Communication:
At end of communication, replace handset
on cradle properly. If not on the hook, call tone will ring and
the channel is established to door for 2-1/2 minutes.
• Cleaning:
Clean MK-1SD/B with a soft cloth dampened with
neutral household cleanser.Never use any abrasive cleaner or
cloth.
SPECIFICATIONS
Power source:
Supplied by main monitor station.
Call-in:
4-tone chime, adjustable to 3
positions. 30 seconds timed.
Communication:
2-1/2 minutes timed.
Wiring:
4 conductors, communication only.
5 conductors (total), communication
6 door strike
Distance:
MK-1SD/B to main monitor
Main monitor
O.eSmmo
I.Ommo
22AWG
18AWG
To MK-1MD/A
50m
lOOm^
165’
330’
To KA-1MD
50m
100m
165’
330’
Dimensions & weight:
: PS-24E
or
PS-24ME.
21 OH
X
lOOWx 74D (mm)
(8-1/4”Hx4”Wx3”D),
415g (0.91 lbs.) approx.
t
WARRANTY
^ Aiphone warrants its products to be tree from defects of material and workmanship under normal use and service for a
4- period of one year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it
♦f- become defective upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself
the sole right to make the final decision whether there is a defect in materials and/or workmanship; and whether or not the
4- product is within the warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in
violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This
warranty does not cover batteries or damage caused by batteries used in connection with the product.
This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by
Aiphone.
Aiphone will not be responsible for any costs incurred involving on site service calls.
4*
4*
4-
4-
4*
4*
Aiphone Co., Ltd. Nagoya, Japan
Aiphone Corporation, Bellevue, WA, USA
Aiphone Europe N.V., Antwerp, Belgium
MK-1SD/B-I(E) 0398A
COMMUNICATION SYSTEMS
AIPHONE
HOME, BUSINESS, INDUSTRY.