Converting of Broiling Burner

• Unplug the main supply cord of the range.
• Remove the screw and washer holding the burner in place (See Figure 7).
• Pul) out the burner until it releases.

• Remove the orifice using a 7mm~spanner socket. Replace the orifice supplied with the

range. For the mark of orifice, see Table 1.

• Replace the burner and the guard in the oven. Replace the washer and tighten the screw.

Be sure that the guard sits completely in place while doing this.

• Keep the remaining orifice in its plastic bag for future use.

> Gas Connection

Figure 8

------ Fl«xibl»

Conn«ctOf

V

Gas connection must be made in accordance with local codes
or in absence of local codes, with the National Fuel Gas Code,

ANSI Z223.1-Latest Edition.
Connect gas supply to regulator using a flexible connector, as
shown in Figure 8. Pressure regulator supplied with this range
has a 1/2-inch NPT female connection.

A manual shutoff, not supplied with this range, must be

installed In an accessible location outside of the range.
Use joint compound that is resistant to action of natural or
propane gas on all mate pipe threads.
Use supplied pressure regulator only.
Do not over tighten gas fitting when attaching to pressure

regulator. Over tightening may crack regulator.

Appliance and individual shutoff valve must be disconnected

from the gas supply piping system during any pressure testing
of that system at test pressures in excess of 1/2 psi (3.5 kPa).

Appliance must

be isolated from gas supply piping system by loosening manual shutoff

valve during any pressure testing of the gas supply piping system at test pressures equal
to or less than 1/2 psi (3.5 kPa).

Gas supply pressure for checking regulator setting must be at least 1-inch water column

above manifold pressure shown on nameplate.
After final gas connection is made, turn on manual gas valve and test all connections in
gas supply piping and range for gas leaks.

In order to avoid property damage or serious personal injury, never use a lighted match.
If a leak is present, tighten joint or unscrew, apply more joint compound, tighten again

and retest connection for leak.

negulatof

Adaptor

Adaptor

. || U

mu

M

, ) ähul 9tt

■ j Vitv.

3.'4" ServicB

Pipe Stub

> Electrical Connection

Electrical connection must be made in accordance with local codes or in absence of local

codes, with the National Electrical Code, ANSlINFPA No.70-Latest Edition.

Connect the 2-prong supply cord to a 120-volt, 60 Hz, 2-prong wall receptacle.

Electrical connection must not interfere with gas connection. (See “Before installation”
user's guide)

Warning

\ ^

Improper use of the grounded plug can result in a risk of electrical shock. If the power cord is

damaged have it replaced by an authorized Avanti Products service center.______________________