Temperature monitoring – Compaq RAID ARRAY 3000 EK-SMCPO-UG. C01 User Manual
Page 58
2-24 RAID Array 3000 Pedestal Storage Subsystem Hardware User’s Guide
Compaq Confidential – Need to Know Required
Writer: Bob Young Project: RAID Array 3000 Pedestal Storage Subsystem Hardware User’s Guide Comments:
Part Number: EK-SMCPO-UG. C01 File Name: c-ch2 RAID Array Controller.doc Last Saved On: 12/4/00 1:51 PM
12 V Supply Voltage
The controller monitors the incoming 12-volt levels and ensures that they are
satisfactory for operation. The acceptable voltage levels are listed in
Table 2–9.
Table 2-9
Acceptable 12 Volt Levels
State
Range
Action
Normal
10.80 to 13.80 V
Normal operation
Low warning
10.20 to 10.80 V
Alarm
High warning
13.80 to 14.40 V
Alarm
Low severe
Less than 10.20 V
Off line
High severe
Greater than 14.40 V
Off line
Temperature Monitoring
External Temperature
The controller monitors the external operating temperature and ensures that
they are satisfactory for controller operation. The acceptable temperature
levels are listed in Table 2-10.
Table 2-10
Acceptable External Temperature Levels
State
Temperature
Action
Normal
< 106ºF (41ºC)
Normal operation
High warning
< 106ºF to 126ºF
(41ºC to 52ºC)
Alarm
High severe
> 133ºF (52ºC)
Off line