Pedestal Components
The major components in the pedestal subsystem include:
■
Dual-channel RAID array controller
■
Two 16-bit single-ended split SCSI buses
■
Environmental Monitor Unit (EMU)
■
Two universal 50/60 Hz, 120 or 240 VAC power supplies
■
Separate free-standing backup power supply (UPS)
StorageWorks Building Blocks (SBBs)
The pedestal has seven 3½-in disk drive SBB slots. The number of drives that
make up each configuration of the array is left to the end user with a maximum
of seven storage devices.
RAID Array Controller
The controller contains two wide,UltraSCSI differential host channels and two
wide, UltraSCSI single-ended disk channels. In dual-controller configurations,
the controllers support fully automatic and smooth controller failover.
The controller supports one or two standard 72-pin cache SIMMs of up to
32
MB. In a redundant controller setup, both controllers must have identical
cache configurations and the total usable cache (per controller) will be half the
amount installed. Thus, in a single controller setup, the maximum usable cache
is 64 MB while a redundant setup has a maximum usable cache of 32 MB (per
controller).
The RAID Array controller contains the following features:
■
Single PCB form factor for inclusion in the enclosure
■
Support for dual hot-swap controller operation
■
Dual differential Ultra-Wide SCSI host channels
■
Dual single-ended Ultra-Wide SCSI disk channels
■
RAID level 0, 1, 0+1, 4, 5, and JBOD support
■
EMU support
■
Cluster support for Windows