Log splitter, Valve in open position, Breather plug and valve – MTD 249-640A User Manual
Page 8
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
FIGURE 14
LOG SPLITTER:
The oil in the reservoir should be changed every (100)
hours of operation.
Check oil in log splitter reservoir before every use;
See figure 16.
1.
Block up front of log splitter so beam is setting
level.
2.
Remove check pipe plug in rear of beam. See
figure 16. If oil starts to come out of check
pipe plug hole, oil level is correct. IF NOT add
oil to breather tube (figure 14) until oil starts out.
NOTE
Use hydraulic sealant tape or pipe
sealant on pipe plug threads.
3. Replace check pipe plug, remove block frorp
under front of beam.
3. Open the breather valve. Valve must be open when
running log splitter. Valve must be closed when
transporting log splitter. See figure 15.
VALVE IN OPEN
POSITION
VALVE IN CLOSED
POSITION
BREATHER PLUG AND VALVE.
NOTE: Valve has left hand threads.
Clockwise to close.
FIGURE 15
FIGURE 16