Changing the light bulb, Removing bulb, Replacing bulb – SINGER 5102 User Manual
Page 29
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

• Bobbin and Feed Areas
To clean bobbin and feed areas, remove nee
dle plate, as instructed on page 5. Using soft
cloth or brush, clean area as illustrated.
Replace needle plate, as instructed on page 5.
• Exterior Areas
If necessary, a mild solution of soap and
water may be used on exterior areas to
remove stubborn stains. No other cleaning
liquid or powder should be used.
CHANGING THE LIGHT BULB
CAUTION: Before changing light bulb make sure
you have disconnected power line plug from
socket outlet.
Removing Bulb
CAUTION: This machine is designed to use a 15
watt maximum bayonet base bulb
only.
Replacing Bulb
• Swing open face plate to left.
• Do
not attempt to unscrew the bulb.
• Press it up into the socket and at the same
time turn bulb over in direction shown to
unlock the bulb pin and guide out of socket.
• Press new bulb into socket, with bulb pins en
tering slot of socket.
• Turn it over in direction shown to lock bulb in
position.
• Swing face plate back to right and snap it
closed.
27