beautypg.com

Compaq 3000 User Manual

Page 33

background image

Chapter 1. Product Overview

EK–SMCPQ–UG. C01

1–21

Table 1–2 Shelf Technical Specifications (continued)

Feature

Description

Regulatory approvals

EMI/R I -- FCC Class A, CSA 108.8 Class A, VCCI level 1,
BICQ Class A, CISPR-22 Class A, C-Tick Class A

Safety -- UL 1950 3

rd

edition, AS/NZ 3260, IEC 950 CSA

22.2 #950,1995, EN60950/A3:1995, VDE 0905, TUV, GS
Mark, CE mark

Table 1–3 Controller Shelf Power and Physical Specifications

Operating Environment

Specification

Power required

110-120/220-240 VAC, 50/60 Hz, Single Phase,
Two 180 Watt power modules @ 2.5 / 1.2 A each

Temperature -- optimal,

Temperature --minimum re-
quired

18 to 24° C ( 65 to 75° F)
10 to 40° C (50 to 104° F )

Relative humidity – optimal

Relative humidity – minimum
required

40% to 60% non condensing

10% to 90% non condensing
Maximum wet bulb temperature 28

o

C (82

o

F)

Minimum dew point: 2

o

C (36

o

F)

Altitude

Up to 8,000 ft (2,400 m)

Inlet air volume

0.026 cubic meter per second (50 cubic feet per mi-
nute)

Air quality

Not to exceed 500,000 particles per cubic foot of air
at a size of 0.5 micron or larger

Non-operating Environment

1

Temperature

-40 to +66° C ( -40 to 151° F)

Relative humidity

8% to 95% non condensing in original shipping con-
tainer

Altitude

From –300 m to 3,600 m (-1,000 ft. to 12,000 ft )

Physical Characteristics

1

Installed Dimensions

Controller and disk shelves

UPS

- Height

150 mm (5.9 in) /4 U

8.9mm (3.5 in) /2U

- Width

445 mm (17.5 in)

48.2mm (19 in)

- Depth

350 mm (13.8 in)

40.6mm (16.0 in)

- Weight

Controller shelf 9.5kg (21
lbs.)
Disk shelf 7.3 kg.(16 lbs.)

UPS 27kg (58 lbs.)

(1) Disk SBBs not included