Frozen water pipe hazard, Warning, Installation – Sears N8MPL050B12B1 User Manual
Page 4: Location and clearances, A warning, Installation requirements
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Frozen Water Pipe Hazard
WARNING
FROZEN AND BURST WATER PIPE HAZARD
Failure to protect against the risk of freezing could
result in property damage.
Do not leave your home unattended for long periods
during freezing weather without turning off water
supply and draining water pipes or otherwise
protecting against the risk of frozen pipes and
resultant damage.
If your furnace remains off for an extended time, the pipes in your
home could freeze and burst, resulting in serious water damage.
If the structure will be unattended during cold weather you should
take these precautions.
1
.
Turn off the water supply to the structure and drain the water
lines if possible and add an antifreeze for potable water to
drain traps and toilet tanks. Open faucets in appropriate
areas.
-or-
2
.
Your furnace is designed solely to provide a safe and comfortable
living environment. The furnace is NOT designed to ensure that
water pipes will not freeze. It is equipped with several safety de
vices that are designed to turn the furnace off and prevent it from
restarting in the event of various potentially unsafe conditions.
2. Installation
Have someone check the structure frequently during cold
weather to make sure it is warm enough to prevent pipes
from freezing. Instruct them on a service agency to call to
provide service, if required.
-or-
Install a reliable remote sensing device that will notify some
body of freezing conditions within the home.
WARNING
CARBON MONOXIDE POISONING HAZARD.
Failure to properly vent this furnace or other
appliances could result in death or personal injury.
If this furnace is replacing a previously common-
vented furnace, it may be necessary to resize the
existing vent system to prevent oversizing
problems for the other remaining appliances(s).
See
Venting and Combustion Air Check'm
the 5.
Gas
Vent Installation
section of this instruction.
Location and Clearances
If furnace is a replacement, it is usually best to install the furnace
where the old one was. Choose the location or evaluate the exist
ing location based upon the minimum clearance and furnace di
mensions (Figure 1 or Figure 2).
A WARNING
CARBON MONOXIDE POISONING HAZARD.
Failure to follow safety warnings could result in
death or personal injury.
Do NOT operate furnace in a corrosive
atmosphere containing chlorine, fluorine or any
other damaging chemicals which could harm the
furnace and vent system, and permit spillage of
combustion products into an occupied space.
Refer to
4. Combustion & Ventilation Air
section.
Contaminated Combustion Air for combustion air
evaluation and remedy.
Installation Requirements
1. Install furnace level.
2. This furnace is NOT to be used for temporary heat of buildings
or structures under construction.
3. Install furnace as centralized as practical with respect to the
heat distribution system.
4. Install the vent pipes as short as practical. (See 5. Gas Vent
Installation section).
5. Do NOT install furnace directly on carpeting, tile or other com
bustible material other than wood flooring.
6. Maintain clearance for fire safety and servicing. A front clear
ance of 24 " is minimum for access to the burner, controls and
filter. See clearance requirements in Figure 1 or Figure 2.
7. Use a raised base if the floor is damp or wet at times.
8. Residential garage installations require:
•
Burners and ignition sources installed at least 18 " (457
mm) above the floor.
•
Furnace must be located or physically protected from
possible damage by a vehicle.
9. If the furnace is to be suspended from the floorjoists in a base
ment or a crawl space or the rafters in an attic, it is necessary to
use steel pipe straps or an angle iron frame to attach the fur
nace. These straps should be attached to the furnace bottom
side with sheet metal screws and to the rafters or joists with
bolts. The preferred method is to use an angle iron frame
bolted to the rafters orjoists.
10. This furnace may be used for construction heat provided that:
•
The furnace is permanently installed with all electrical
wiring, piping, venting and ducting installed according to
these installation instructions. A return air duct is pro
vided, sealed to the furnace casing, and terminated out
side the space containing the furnace. This prevents a
negative pressure condition as created by the circulating
air blower, causing a flame rollout and/or drawing com
bustion products into the structure.
•
The furnace is controlled by a thermostat. It may not be
"hot wired" to provide heat continuously to the structure
without thermostatic control.
•
Clean outside air is provided for combustion. This is to
minimize the corrosive effects of adhesives, sealers and
other construction materials. It also prevents the entrain
ment of drywall dust into combustion air, which can cause
fouling and plugging of furnace components.
•
The temperature of the return air to the furnace is main
tained between 55° F (13° C) and 80° F (27° C), with no
evening setback or shutdown. The use of the furnace
while the structure is under construction is deemed to be
intermittent operation per our installation instructions.
441 01 2613 02
- N8MPL075B12B1 8MPL050B12B1 N8MPN100J22B1 N8MPL125J20B1 8MPL075F16B1 N8MPN100F14B1 N8MPL100J22B1 8MPN125J20B1 N8MPN075F16B1 8MPN075B12B1 N8MPN125J22B1 8MPN100F14B1 8MPN100F20B1 N8MPN125J20B1 N8MPL100F20B1 8MPL075B12B1 8MPL125J20B1 N8MPN050B12B1 8MPN050B12B1 N8MPL125J22B1 8MPN075F16B1 8MPN150J20B1 8MPN100J20B1 N8MPN075B12B1 N8MPL075F16B1 8MPL100F20B1 N8MPN100F20B1 8MPL100J20B1