beautypg.com

Maintenance, Cooling system, Air cleaner – Sears 917.299642 User Manual

Page 14: Muffler, Spark plug

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

MAINTENANCE

A

DISCONNECT SPARK PLUG WIRE
FROM SPARK PLUG BEFORE PER­
FORMING ANY MAINTENANCE (EX­
CEPT CARBURETOR ADJUSTMENT)

TO PREVENT ACCIDENTAL START­

ING OF ENGINE.

PREVENT FIRES! KEEP THE ENGINE
FREE OF GRASS, LEAVES, SPILLED
OIL, OR FUEL. REMOVE FUEL FROM
TANK BEFORE TIPPING UNIT FOR
MAINTENANCE.

CLEAN

MUFFLER

AREA OF ALL GRASS, DIRT, AND DE­

BRIS.

DO NOT TOUCH HOT MUFFLER OR
CYLINDER FINS AS CONTACT MAY
CAUSE BURNS.

COOLING SYSTEM

Your Engine is air cooled. For proper Engine performance

and long life KEEP YOUR ENGINE CLEAN,

• Clean Air Screen (Fig,. 21) frequently using a stiff bristled

brush,

• Remove Blower Housing and clean as necessary,.

• Keep Cylinder Fins free of dirt and chaff.

AIR CLEANER

Replace Air Cleaner Cartridge every twenty-five hours,

more often if Engine is used in very dusfy conditions:

• Loosen Air Cleaner Screws, one on each side of Cover

(Fig. 22).

• Remove Air Cleaner Cover

• Carefully remove Air Cleaner Cartridge. Be careful. Do

not allow dirt or debris to fall into Carburetor.

• (nstaii new Air Cleaner Cartridge. Clean and replace

Cover, Tighten Screws securely.

MUFFLER

Do not operate Tiller without Muffler (Fig. 21), Do not

tamper with exhaust system. Damaged Mufflers or Spark
Arresters could create a fire hazard. Inspect periodicaliy
and replace if necessary. If your Engine is equipped with a
Spark Arrester Screen Assembly, remove every 50 hours
for cleaning and inspection. Replace if damaged.

SPARK PLUG

• The Spark Plug should be changed every 50 hours of

operation or at the beginning of every tilling season.

• Set gap at .030”. Order Spark Plug listed in the Repair

Parts Section of this Manual.

A

SPARKING CAN OCCUR IF SPARK
PLUG WIRE TERMINAL DOES NOT
FIT FIRMLY ON SPARK PLUG. RE­
FORM TERMINAL IF NECESSARY.

14