beautypg.com

Carrier Puron 38EYA User Manual

Page 9

background image

G

R

Y/Y2

O/W2

CARRIER

DUAL FUEL

THERMOSTAT

MODEL DF

SINGLE-STAGE

FURNACE

HEAT PUMP

G

Y

W

C

Y

R

O

W2

Y1/W2

C

B

L

S1

S2

R

C

FURNACE

COMPRESSOR

FAN

24 VAC HOT

24 VAC COM

N/A

RVS HEATING

RVS SENSING

OUTDOOR
SENSOR
CONNECTION

OUTDOOR
TEMPERATURE
SENSOR

W/W1

See note 7

RVS COOLING

A97538

G

R

Y/Y2

O/W2

CARRIER

DUAL FUEL

THERMOSTAT

MODEL DF

TWO-STAGE OR

VARIABLE SPEED

FURNACE

HEAT PUMP

G

C

Y

R

O

W2

Y1/W2

C

B

L

S1

S2

R

C

O

W2

Y1

FURNACE LO

COMPRESSOR

FAN

24 VAC HOT

24 VAC COM

FURNACE HI

RVS HEATING

RVS SENSING

OUTDOOR
SENSOR
CONNECTION

OUTDOOR
TEMPERATURE
SENSOR

W/W1

W/W1

Y/Y2

See notes 7 and 8

RVS COOLING

A97539

Fig. 14—Typical 24-v Circuit Connection using Carrier Model DF Thermostat with Single- or 2-Stage Furnace

Fig. 15—Typical 24-v Circuit Connections using Carrier Model 2S Thermostat

with FV4A Fan Coil and Smart Staging

A97565

24 VAC HOT

R

G

W/W1

Y/Y2

Y/Y2

Y1/W2

R

DH

RVS COOLING

C

B

L

S1

S2

Y

W2

CARRIER

PROGRAMMABLE

THERMOSTAT

MODEL 2S

FV4A

FAN COIL

HEAT
PUMP

G

O

O/W2

W2

Y1

C

W1

R

O

24 VAC COMM

HEAT STAGE 2

HEAT STAGE 3

COOL/HEAT
STAGE 1

FAN

RVS HEATING

TROUBLE

OUTDOOR
SENSOR
CONNECTION

C

J1 JUMPER

REMOVE

J2 JUMPER

FOR HEAT

STAGING

Smart Sequencing Application: Model 2S thermostat with
switch C OFF and switch D ON uses single-speed heat pump,
FK4 fan coil with selected 2:1 size ratio heaters. Provides 3
stages of auxiliary heat for even heating comfort via W/W1
and Y1/W2. Refer to FK4 Installation Instructions.

9