HEATING A COOLING
50ET,QT
Single-Package Units
Table 1 — Electrical Data (60 Hz)
MODEL
50ET/QT
V/PH
OPER
VOLTS*
CO^flPR
iPM
OFM
ELECTRIC
HEATER
BRANCH CiRCUiT #1
(or Total Unit)
BRANCH CiRCUiT #2
(When Used)t
Max
Mint
LRA
RLA
FLA
FLA
kW
Amps
Max TD Fuse or
HACR CktBkr Amps**
MCA
Max TO Fuse or
HACR CktBkr Amps**
MCA
212300
208/230/1
254
187
37
68
1 5
1 0
None
30
5.0
9 4/12 5
18.0/20.8
15/15
25/30
35/40
110/110
22 8/26 6
33,5/37.0
-
-
215300
208/230/1
254
187
43
87
1 5
1 0
None
30
50
9 4/12 5
18 0/20 8
20/20
25/30
35/40
13 4/13 4
25 1/29 0
35 9/39.4
—
—
218300
208/230/1
254
187
50
9 3
1 7
1 5
None
30
50
7.5
9 4/12 5
18 0/20 8
26.8/31.3
20/20
30/35
40/45
50/60
14 8/14 8
26 6/30 5
37 3/40 8
48.3/54.0
-
-
224300ft
208/230/1
254
187
59
130
2 0
1 5
None
50
7 5
100
17 3/20 8
26 8/31 3
36 1/41 7
15/15
25/30
35/40
50/60
2 5 / 2 5
24 1/28 5
36 0/41 6
47 6/54 6
25/25
25/25
25/25
25/25
17 9/17 9
17 9/17 9
17 9/17 9
17.9/17 9
230300ft
208/230/1
254
187
79
169
2 4
1 5
None
50
7 5
10.0
17 4/20 8
26 8/31 3
36.0/41.7
15/15
30/30
40/40
50/60
3 0 / 3 0
24 8/29 0
36 5/42 1
48.0/55.1
35/35
35/35
35/35
35/35
25/25
25/25
25/25
25/25
FLA — Full Load Amps
HACR — Heating, Air Conditioning and Refrigeration
IFM — Indoor Fan Motor
LRA — Locked Rotor Amps
MCA — Minimum Circuit Amps
OFM — Outdoor Fan Motor
RLA — Rated Load Amps
TD — Time Delay
‘Permissible limits of the voltage range at which units will operate
satisfactorily
Table 2 — Accessories
PART NO.
DESCRiPTiON
MODEL 50ET.QT
500T902061
\A/all Sleeve (one)
212, 215, 218
50QT900081
Wall Sleeve (one)
224, 230
50QT90301106
Standard Aluminum Grille (six)
All
500T90302106
Architectural Grille (six)
All
S0QT90400102
Polymer Front Cover (two)
212, 215, 218
50QT90401102
224, 230
50QT90700106
Fresh Air Damper (six)
All
50QT905001
Cold Climate Package (one)
All
Cooling Thermostats:
99TZ900321/
99TZ900361*
Automatic Changeover
All
99TZ900321/
99TZ900391*
Manual Changeover
All
99TZ900291*
Heat Pump Thermostats:
Two-Stage Heat, One-Stage Cool
Manual Changeover
99TZ900401*
Automatic Changeover
99TZ900511*
Manual Changeover
All
99TZ900501*
Electronic, 7-Day Programmable
99TZ900541t
Manual Changeover
50QT901000
Electric Heaters (kW)
3
212, 215, 218
50QT901010
5
212, 215, 218
50QT901020
75
218
SOQT901030
5
224
50QT901040
7 5
224
50QT901050
10
224
500T901060
5
230
50QT901070
7 5
230
50QT901080
10
230
'For remote mounting only
tSuitable for mounting on unit chassis
SLIDE CHASSIS INTO SLEEVE — Chassis is heavy.
Portable lifting device must be used. Exercise caution
to be sure forks do not damage chassis components (such
as drain connections) while lifting and installing. Guide
chassis into sleeve on indoor side by first placing chassis
guide channels onto lower corners of sleeve. Slide chassis
into sleeve until center partition perimeter meets gasket
provided around outer edge of sleeve. Check electrical
plugs for alignment as chassis is slid into place.
tMinimum voltage Is 197 when outdoor ambient temperature exceeds
105 F
^iFiold wiring to be sized per NEC or local codes Use copper wire only
"Maximum dual element fuse size
ttThese units require 2 separate supply circuits Refer to both branch
circuit charts for complete electrical data Two-circuitfused disconnect
must be field supplied
NOTE: Dual values in this table (for example: Electric Heater Amps:
9 4/12 5) apply to 208- and 230-volt connections, respectively
w
Fig. 1 — Chassis with Accessory Indoor
Polymer Wrapper
A WARNING
Do not release chassis until installed and bolted
completely into sleeve as it may fall out without
warning.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obiigations.
Bookll II 14 14
PC 131 Catalog No 535-078 Printed in U S A Form 50ET.QT-3SI Pg2 5-85 Replaces: 50QT-10SI
Tab 1b 5al1a|5a
For replacement items use Carrier Specilied Parts