Indooitcbil, Electric heaters, Single point box – Carrier 50YX User Manual

Page 4: Service sentry™ kit, Outdoor thermostat kit, Thermostat and subbase

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

(òlwillll

UNITJOYX

Ml^lGERiS^f]R-22)*

Refrigerant Control

WEIG^

COMPRESSOR

INDOOR FAN

Speeds
Rpm
Diameter (in.)
Width (in.)
Nominal Range (cfm)

Motor Hp

iNDOOiTcbiL^.

Rows...Fins/in.
Face Area (sq ft)

OUTDOOR FAN ^

Cfm

Rpm
Diameter (in.)

JWotor Hp

OUTDOOR ^¡L

Rows...Fins/in.

^ace Area (^ft)

FILTER SIZE (in.jt

(Qty) Throwaway

018

330

2

840

10

6

525-750

V4

3 15

34

024

030

036

042

048

TXV

" 336

340

’^~407

423 "

Scroll

Centrifugal — Direct Drive

2

2

2

2

3

840

840

840

840

1100

12

12

12

12

12

6

6

6

6

6

700-1000

875-1250

1050-1500

1100-1650

1400-1800

Va

Va

V2

V2

Va

3 .15

3

..15

3...15

3 ..15

3. .15

34

3.4

4.7

6.0

65

(Qty) Permanent

LEGEND

TXV —

Thermostatic Expansion Vaive

‘Operating charge is listed on unit nameplate.
fRecommended field-supplied filters are one-in thick.

Propeller — Direct Drive

2200

840

22

Vs

2200

840

22

V4

2700

1100

22

V4

2700

1100

22

1/4

3200

1100

22

1/4

3200

1100

22

1/4

3400

1100

22

1/2

2..17

8.3

2 17

83

2. .20

8 3^__

2. 20

96

2...17

12.0

2.17

12.7

2.. 17

12.7

(1) 20

X

25

(1) 20

X

25

(2) 15

X

20

(1) 15

X

20

(1) 20

X

20

(2) 20

X

20

(1) 20

X

25

(1) 25

X

25

(1) 20

X

25

(1)25x25

(1) 15

X

20

(1) 15

X

20

(2) 20

X

20

(2) 20

X

25

(2) 20

X

25

(2) 20

X

20

(2) 20

X

20

060

432

2

1100

12

6

1750-2400

%

4...15

6.4

Electric heaters

that mount inside the heat pump indoor-

fan compartment are available in a variety of kW and volt­
age options. Each heater assembly includes automatic-reset
switch, and heat limiters for primary and secondary, over­
current, and thermal protection

Single point box

allows for a single power supply for the

base unit and accessory electric heater, and functions as an
NEC-approved fused disconnect

Service Sentry™ kit

provides immediate warning when

the compressor fails to operate after a call for heating or
cooling The control energizes a warning light located on the
indoor thermostat

Outdoor thermostat kit

allows for staging of electric heat­

ers based on outdoor-air temperature

Thermostat and Subbase

provides heating and cooling

unit control Automatic and manual changeover types are
available

ACCESSORY

PART NO.

Electric Heater 5.0 kW

7.5 kW

10.0 kW
15.0 kW
20.0 kW

88EMOO5OMAO0
88EM0075MA00
88EM0100MAOO
88EM0150MA00
88EM0200MAOO

Single Point Box

For 5.0-kW Heaters (Unit Sizes
018,024)

50YX-900—001

For 7.5- and 10.0-kW Heaters

(Unit Sizes 018,024); For 5.0-kW
Heaters (Unit Sizes 030-060)

50YX-900—002

For 7.5- and 10.0-kW Heaters
(Unit Sizes 030-048)

50YX-900—003

For 15.0-kW Heaters (Unit Sizes
030-060); For 20.0-kW Heaters
(Unit Sizes 036-060)

50YX-900—004

Thermostat and Subbase
Autochangeover

99TZ-900—521

Thermostat and Subbase,
Manual Changeover

99TZ-900—571

Service Sentry™ Kit

50LQ-900—011

Outdoor Thermostat

50LQ-900—001