C^pac^iii©s – Carrier 50YX User Manual
Page 3
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

50YX 024
3
Model Number
50YX—High
Efficiency
Single-Package
Heat Pumps
Nominal Capacity
018 —1 1/2 Tons
024 — 2 Tons
030 — 2 1/2 Tons
036 — 3 Tons
042 — 3 1/2 Tons
048 — 4 Tons
060 — 5 Tons
V-Ph-Hz
3-208/230-1-60
c^pac^iii©s
COOLING AND HEATING CAPACITIES AND EFFICIENCIES
UNIT
50YX
NOMINAL
TONS
STANDARD
CFM
NET COOLING*
CAPACITIES
AT 95 F (Btuh)
SEER*
NET HEATING*
CAPACITIES
AT 47 F (Btuh)
COP*
AT 47 F
NET HEATING*
CAPACITIES
AT 17 F (Btuh)
COP*
AT 17 F
018
1У2
600
18,500
12 0
17,200
30
9,300
1,8
024
2
900
24,800
120
21,500
30
12,000
1 8
030
2Уг
1100
31,000
12 1
29,000
3 1
16,800
20
036
3
1300
35,800
120
34,000
3,0
19,000
1,9
042
ЗУ2
1400
41,500
12,0
38,600
32
21,500
20
048
4
1600
48,500
12,0
46,000
32
27,000
20
060
5
2000
60,000
11 0
54,500
30
31,000
1,9
HSPF
70
7,0
'7T
7 0
70
73
70
SOUND
RATINGSt
(Bels)
76 ■'
^ I
82
8 O"
ARI
Bels
COP
DOE
HSPF
SEER
LEGEND
Air-Conditioning & Refrigeration Institute
Sound Levels (1 bel = 10 decibels)
Coefficient of Performance
Department of Energy
Heating Seasonal Performance Factor
Seasonal Energy Efficiency Ratio
‘Rated in accordance with ARI Standard 210/240-89 and/or U.S Gov
ernment DOE test procedures
tRated in accordance with ARI Standard 270-84
NOTE, Ratings are net values, reflecting the effects of circulating fan
heat Ratings are based on cooling standard 80 F db, 67 F wb indoor
entering-air temperature and 95 F db outdoor entering-air temperature.