Selection procedure (with example)

I Determine job requirements.

IV Adjustments to capacities and Kw's for additional indoor fan

Estimated requirements

motor heat for statics above 0.2 in. wg at listed cfm's.

Cooling load - total capacity................................... 54,000 Btuh

The .754 electric heater

resistance at 2,000 cfm is

0 26

- sensible capacity........................... 42,000 Btuh

'"■ ^9

n"

Outside air temperature (Cooling).....................................95 F

operate at 2,000 cfm with 0.66 ESP to overcome the

Air entering indoor coil (Cooling) wb ................................ 64 F

heater pressure drop.

gQ p

From the fan tables at 2,000 cfm with 0.66 ESP requires

Air quantity (cfm)........................................................2,000

1,208 rpm, 1,130 watts.

External static pressure - ESP (in. wg) ................................. 0.4

NOTE For PQ units or RQ units with

plenums, use PQ fan

Heating load........................................................... 60,000 Btuh

fable at required ESP.

Outdoor temperature (winter design)............................. —10 F

ESP

IFM Kvy

Air entering indoor coil (Heating).......................................70 F

2,000 cfm *.2

83

Power supply .............................................................. 230-3-60

.66

1.13

_

.

. .

(Diff in Kw) =

0 30

etermine unit size.

^

*NOTE Use motor Kw from RQ fan tables for .2 in ESP at

Select unit on cooling capacity.

specified cfm for all plenum applications.

Enter the cooling capacity table at the given air quantity

Adjust all capacities for additional

IFM heat at higher

and evaporator entering wet bulb (2,000

cfm, 64 ewb).

statics than .2 in. wg.

Read across table for net total capacity (TC) and net

Diff (Btuh) = 3 413Btu/Kw x Kw

sensible capacity (SHC), under the condenser entering air

^ 3 413 x 30 = 1 024 Btuh

temperature

(95

F) to find by interpolation TC of

56,000

rnni INC

and SHC of

47,400

at

2,000

cfm,

64

F wb for the

, ,

RORonnK

Adjusted TC = TC — Diff (Btuh)

,

,

, ,

= 56,000-1,024 = 54,976 Btuh

Since these net capacities have been calculated at 0.2 in. wg

Adjusted SHC = SHC — Diff (Btuh)

external static (ARI condition), for any additional static —

^ 4

qq

_ ^ Q24 = 4g 375

the net capacities must be adjusted to reflect the resulting

Adjusted power input = Kw* + Diff '

IFM heat. To obtain the total required static,all accessory

^ 7 g + g 30

8 1 Kw

pressure drops must be calculated. Therefore, calculation

*Kw-unit total from 'cooling capacity table at selected

of heater requirements must be made since pressure drop

conditions

varies for each size of electric heater.

HEATING

III Heating requirements

number of electric heaters required.

Adjusted heating capacity = 18,000 -1- 1,024 = 19,024

Enter instantaneous/integrated heating ratings at 006 size

Adjusted power input

= Kw** -t Diff (Kw)

and 2,000 cfm. Under temperature at air entering outdoor

= 4 2 - t 30 = 4 5 Kw

coil, -10 F, the Integrated heating capacity is 18,000 Btuh.

**Kw from heating capacity tables of selected conditions.

The heating load is 60,000 Btuh, therefore, 42,000 Btuh

V Corrections to SHC for dry bulb above or below 80 F

-

see

additional electric heat is necessary. Enter electric resist-

SHC correction factor table.

For this example, no correction

ance heater capacity table at 006 size and 230-3-60. The

is necessary since the entering dry bulb is 80 F.

.754 heat ratio/or 13 Kw electric heater most closely

Therefore, the final net capacities are

satisfies the electric heater requirement.

SHC = 46,376 Btuh

13Kwor

— 44,400 Btuh (from Electric

TC = 54,976 Btuh

Heating Capacities Table)

The 50RQ at the required design conditions has enough

44,400 -t- 18,000 — 62,400 Btuh

sensible capacity for the job application.

Performance data

ARI CAPACITY RATINGS

COOLING

HTG (Hi -Temp)

HTG(L o-T emp)

UNIT

CFM

Cap. .

(Btuh)

EER

Cap.

(Btuh)

C.O.P.

Cap.

(Btuh)

C.O.P.

50RQ

006

2000

59,000

7.5

62,000

2.8

35,000

2.0

50RQ

008

3000

88,000

7.8

91,000

2.8

51,000

2.0

SORQ

010

3Ó00

108,000

7.7

11 2,000

2.8

61,000

2 0

SOPQ

006

2000

59,000

7.4

62,000

2.8

35,000

1.9

SOPQ

008

3000

87,000

7 6

92,000

2.8

52,000

2 0

50PQ

010

3600

1 07,000

7 5

113,000

2.8

62,000

2 0

Rated in accordance with

ARI Standard 240-75.

Ratings are net values, reflecting the effects of circulating fan heat

Supplementary electric heat is not included, Ratings are based on:

Cooling Standard:

80 F db, 67 F wb indoor entering air temperature

and 95 F db air entering outdoor unit

Hi-Temp Heating Standard:

70 F db indoor entering air temperature

and 47 F db, 43 F wb air entering outdoor unit

Lo-Temp Heating Standard:

70 F db indoor entering air temperature

and 17 F db, 1 5 F wb air entering outdoor unit