ACCESS/FIOP STATIC PRESSURE LOSSES (in. wg)
INDOOR FAN DRIVE DATA
UNIT
50RQ,P<5
006
008
010
HEATERS
CFM
1.5:1.0
Low
.75:1
1.0:1.0
1800
13
21
21
25
2000
16
26
26
32
2500
24
42
42
48
2700
09
11
1 1
17
3000
10
13
13
20
3700
15
22
22
30
3200
.12
15
15
.23
3600
.15
.20
20
.28
I 4500
.29
.35
35
.45
PLENUM*
14
17
25
^^21
25
41
16
.24
*Standaid on 50PQ, accessory on 50RQ Standard filter pressnie
drop included in plenum
ELECTRIC HEATING CAPACITIES*
UNIT
VOLTS/
HTR
TOT.
KWt
BTUH
KWt
BTUH
PHASE
SIZE
KW Stage 1 (1000) Stage 2 (1000)
Low
6.4
6.4
21.9
—
-
230/
75:1.0
13
13
44.4
-
1
1.0:1 0
20
13
44.4
7
23.9
i.i5:1.0
26
13
44.4
13
44.4
Low
4.4
4 4
15.0
—
200/
.75:1.0
13
13
44.4
-
-
50RQ,
3
1.0:1.0
15
10
34.2
5
17.1
1.5:1.0
26
13
44.4
13
44.4
PQ
-
_ .
006
Low
4.5
4.5
15.4
—
—
230/
75:1.0
13
13
44.4
-
3
1.0:1.0
20
13
44.4
7
23.9
1.5:1.0
26
13
44.4
13
44.4
Low
5.2
5.2
17.8
—
460/
.75:1.0
13
13
44.4
-
-
3
1.0:1.0
20
13
44.4
7
23 9
1.5:1.0
26
13
44.4
13
44.4
Low
6.5
6.5
22.2
—
_
200/
.75:1.0
20
10
34.2
10
34.2
3
1.0:1 0
26
13
44.4
13
44.4
1.5:1.0
39
13
44.4
26
88.8
50RQ,
Low
6.4
6.4
21.9
-
-
PQ
230/
.75:1.0
19
12
41.1
7
24.0
008/
3
1.0:1.0
26
13
44.4
13
44.4
010
1.5:1.0
39
13
44.4
26
88 8
Low
6.4
6 4
21.9
—
-
460/
.75:1.0
19
12
41.1
7
24.0
3
1.0:1.0
26
13
44.4
13
44.4
39
13
44.4
26
88.8
I Available as an accessory only
‘Available as factory-installed option or field-installed accessory ex
cept as noted
I Available if outdoor thermostat is used.
UNIT
50RQ,PQ
TYPE
0
1
FAN
T urns
2
RPM
Open
3
4
5
006
Std
1300
1224
1148
1072
996
920
Alt
1460
1382
1304
1226
1148
1070
008
Std
980~
922
864
806
745
690
Alt
1093
1035
978
920
863
805
010
Std
978
920
863
805
748
691
Alt
1093
1035
978
920
863
805
Electrical data
50RQ, PQ006
V-PH-HZ
Voltage
Range
230-1-60
207-264
200-3-60
180-229
230-3-60
207-264
460-3-60
414-528
575-3-60
51S-660
COMPR
RLA
LRA
35 3
135
22.2
113
20.9
98
10.4
49
8.3
41
OFM
FLA
4.4
5.1
4.4
2.2
4.4
Compr
FLA
Hp
IFM
Kw
LRA
OFM
RLA
‘Fuse only
Compressor
Full Load Amps
Horsepower
Indoor Fan Motor
Kilowatts
Locked Rotor Amps
Outdoor Fan Motor
Rated Load Amps
IFM
FACTORY-
POWERt
INSTALLED
SUPPLY
HEATERS
Min
Max
Hp FLA
Kw
FLA
Ckt
Fuse
Amps Amps
75
6 9
—
—
55
60
1.0
8.0
-
_
57
60
75
6.9
6.4
28
90
90
75
6.9
13.0
55
124
125
.75
6.9
20.0
83
159
150
1.0
8.0
6.4
28
92
90
1 0
8.0
13.0
55
125
125
1.0
8 0
20.0
83
160
150
.75
7.9
_
—
41
50
1 0
9 2
—
—
42
50
.75
7.9
4.4
22
69
75
75
7.9
13.0
55
110
no
75
7.9
15 0
42
94
100
.75
7 9
26.0
83
145
150
1.0
9.2
4.4
22
70
75
1 0
9.2
13.0
55
111
110
1.0
9.2
15.0
42
95
100
1.0
9 2
26 0
83
146
150
.75
6.9
—
_
38
50
1 0
8 0
—
—
39
50
.75
6 9
4.5
19
61
70
.75
6.9
13.0
48
98
100
75
6.9
20.0
48
98
100
75
6 9
26.0
74
130
125
1.0
8 0
4 5
19
62
70
1.0
8.0
13.0
48
99
100
1.0
8 0
20.0
48
99
100
1.0
8.0
26 0
74
131
125
.75
1.4
_
—
17
20
1 0
1 8
_
-
17
20
.75
1.4
5.2
11
30
35
.75
1 4
13.0
25
48
50
.75
1.4
20.0
25
48
50
.75
1.4
26.0
37
63
60
1 0
1.8
5 2
11
31
35
1 0
1 8
13 0
25
48
50
1.0
1.8
20.0
25
48
50
1.0
1 8
26.0
37
63
60
.75
1.1
_
_
16
20
1 0
1
-
-
16
20
1 1