Mtek6000 series user's manual – Compaq MTEK6000 User Manual
Page 65
MTEK6000 SERIES USER'S MANUAL
January 2002 C - 7
It is disabled if set to 0. In this mode, the
EFC should be configured to wake up on the
number of pulses entered along with an
hourly scheduled wake-up to record history
data. Therefore, the wake up interval
(seconds) parameter should be set to 3600.
The Default value is 0.
Units of Measure
The MTEK6000 can be configured to calculate volume and flow with English or Metric units.
The database ca be setup for the following units of measure:
Flow & Volume ft
3
(cubic feet)
Accumulations
M
3
(cubic meters)
Static Pressure
PSI (pounds per square inch)
Kpa
(Kilopascals)
Kg / cm
2
(kilograms per square centimeter)
Bars
MBars
(millibars)
Atmospheres
mmHg (millimeters of mercury)
mmH
2
O (millimeters of water)
MH
2
O (meters of water)
inH
2
O (inches of water)
Temperature*
°
F
°
C
Differential
inH2O (inches of water)
Pressure
mmH2O (mm of water)
Pipe & Orifice inches
Diameter centimeters
* The units for temperature are automatically set for
°
F or
°
C when the units for volume and
flow are chosen. Choosing English units (cubic feet) will set the temperature to F, etc.