Compaq MTEK6000 User Manual
Page 52
MTEK6000 SERIES USER'S MANUAL
A-6
January 2002
Table A-13: Standard display mode and
function keys for MTEK6000
EFM
w/
Aux Press
Label I.D. Description Address
F1 1 CV
Corr Volume MCF 051102
F8 2 DP
Diff Press “H20
040302
F3 3 PR
PRessure PSG
030302
F4 4 FT
Flow Temp F
020304
5 FR
Flow Rate MCH
050302
F6 6 AP
Aux Pressure PSG
020306
7 OD
Orif Diameter IN
050608
F5 8 SV
Supply Volts DC
020309
9 CT
Case Temp F
020302
10 FC
Flow Constant
050601
11 PD
Prev Day vol MCF 050903
12 CD
Curr Day vol MCF 050905
13 PS
Press Scale PSG
020402
14 DS
Dp Scale H20 020404
15 AS
Aux p Scale PSG
020405
Table A-14: Standard alarms for
MTEK6000 EFM w/ Aux Press
Alarms
Alarm Code
First Time Power
180401
Low Supply Volts
180501
High Flow Rate
180601
Low Flow Rate
180701
High Pressure
190401
Low Pressure
190501
High Diff Press
190601
Low Diff Press
190701
High Temperature
200401
Low Temperature
200501
Current Day Flow
200601
Lost Pressure
210401
Lost Temperature
210501
Lost Diff Press
210601
LowVolt Shutdown
210701
Open Door
220401
Software Error
220501
High Aux Press
220601
Low Aux Press
220701
Lost Aux Press
200701
Table A-15: Standard history data
stored in the MTEK6000 EFM w/ Aux
Pressure
40 days of daily corrected volume
40 days of daily average temperature
40 days of daily maximum flow rate
40 days of daily minimum flow rate
40 days of daily average pressure
40 days of daily average aux. pressure
40 days of daily average differential pressure
40 days of hourly corrected volume
40 days of hourly average differential
pressure
40 days of hourly average pressure
40 days of hourly average aux. pressure
40 days of hourly average temperature
40 days of hourly instantaneous supply
voltage (snapshots).
40 days of hourly case temperature
(snapshots)