Table A-13: Standard display mode and
function keys for MTEK6000

EFM

w/

Aux Press


Label I.D. Description Address


F1 1 CV

Corr Volume MCF 051102

F8 2 DP

Diff Press “H20

040302

F3 3 PR

PRessure PSG

030302

F4 4 FT

Flow Temp F

020304

5 FR

Flow Rate MCH

050302

F6 6 AP

Aux Pressure PSG

020306

7 OD

Orif Diameter IN

050608

F5 8 SV

Supply Volts DC

020309

9 CT

Case Temp F

020302

10 FC

Flow Constant

050601

11 PD

Prev Day vol MCF 050903

12 CD

Curr Day vol MCF 050905

13 PS

Press Scale PSG

020402

14 DS

Dp Scale H20 020404

15 AS

Aux p Scale PSG

020405

Table A-14: Standard alarms for
MTEK6000 EFM w/ Aux Press


Alarms

Alarm Code


First Time Power

180401

Low Supply Volts

180501

High Flow Rate

180601

Low Flow Rate

180701

High Pressure

190401

Low Pressure

190501

High Diff Press

190601

Low Diff Press

190701

High Temperature

200401

Low Temperature

200501

Current Day Flow

200601

Lost Pressure

210401

Lost Temperature

210501

Lost Diff Press

210601

LowVolt Shutdown

210701

Open Door

220401

Software Error

220501

High Aux Press

220601

Low Aux Press

220701

Lost Aux Press

200701

Table A-15: Standard history data
stored in the MTEK6000 EFM w/ Aux
Pressure


40 days of daily corrected volume
40 days of daily average temperature
40 days of daily maximum flow rate
40 days of daily minimum flow rate
40 days of daily average pressure
40 days of daily average aux. pressure

40 days of daily average differential pressure

40 days of hourly corrected volume

40 days of hourly average differential
pressure

40 days of hourly average pressure
40 days of hourly average aux. pressure
40 days of hourly average temperature
40 days of hourly instantaneous supply
voltage (snapshots).
40 days of hourly case temperature