vTr8300 And sCs | FAn Coil TerminAl eqUipmenT ConTrollers

Commercial interface (local override)
Power

Part Number

Description

Humidity

PIR Cover

Communication

VTR8300A0Axx

Stand-alone fan coil terminal equipment controller

No

No

Stand-alone

VTR8300A0Bxx

BACnet

®

fan coil terminal equipment controller

No

No

BACnet

®

VTR8300A0Pxx

Wireless fan coil terminal equipment controller

No

No

ZigBee

®

Pro Wireless

VTR8300A5Axx

Stand-alone fan coil terminal equipment controller

No

Yes

Stand-alone

VTR8300A5Bxx

BACnet

®

fan coil terminal equipment controller

No

Yes

BACnet

®

VTR8300A5Pxx

Wireless fan coil terminal equipment controller

Yes

Yes

ZigBee

®

Pro Wireless

VTR8350A0Axx

Stand-alone fan coil terminal equipment controller

Yes

No

Stand-alone

VTR8350A0Bxx

BACnet

®

fan coil terminal equipment controller

Yes

No

BACnet

®

VTR8350A0Pxx

Wireless fan coil terminal equipment controller

Yes

No

ZigBee

®

Pro Wireless

VTR8350A5Axx

Stand-alone fan coil terminal equipment controller

Yes

Yes

Stand-alone

VTR8350A5Bxx

BACnet

®

fan coil terminal equipment controller

Yes

Yes

BACnet

®

VTR8350A5Pxx

Wireless fan coil terminal equipment controller

Yes

Yes

ZigBee

®

Pro Wireless

Transformer relay packs for fan coil units
Power

Part Number

Description

SC3500E5045

1 heat/cool output, 1 cool output, and 3 fan outputs

SC3504E5045

1 heat/cool output, 1 cool output, 3 fan outputs, and four inputs

SC3514E5045

1 heat/cool output, 1 cool output, 3 fan outputs, Occupancy output (7Vdc), and four inputs

SC3400E5045

1 heat/cool output, 1 Modulating pulsed Vdc output for SSR electric reheat control, and 3 fan outputs

SC3404E5045

1 heat/cool output, 1 Modulating pulsed Vdc output for SSR electric reheat control, and 3 fan outputs

SC3300E5045

3 slave fan outputs

Wireless accessories for VTR8300 Series
Power

Part Number

Description

SED-DOR-P-5045

Wireless door switch

SED-WIN-P-5045

Wireless window switch