Nfo i, Ara p – TriangleTube 110 Solo User Manual
Page 54

48
Start-Up Procedures
Accessing Boiler Information
Information mode
To switch from STANDBY mode to INFOR-
MATION mode, press MODE twice.
Press STEP until the system displays the infor-
mation you need. The first digit is the informa-
tion item number followed by the items value.
The decimal point located behind the first posi-
tion flashes to indicate that the boiler is in
INFO mode.
The ignition counters and burner hours
are split into three two digit numbers.
For example:
Write the numbers down from left to right
to arrive at 123,456 CH ignitions.
In the INFO Mode a temperature read-
ing of -22 typically indicates an “open”
circuit. A temperature reading of 240
typically indicates a short-circuit.
NFO
I
NOTICE
NOTICE
ARA
P
MODE
NFO
I
MODE
Key:
Display
Pressing MODE once
Pressing MODE twice
J 12
.34
.56
Display Digit
Segments
Information Mode Items