5.3. Star Connection
Connect the Combination camera's control cable to the unit's Slave Connection Terminal, making sure to
match their polarities.
Remote controller
C-RM500
C-IF500
C-IF500
Combination camera
Combination camera
MASTER
SLAVE
GND
IN
GND
A
GND
B
GND
C
GND
D
GND
OUT
OFF
TERMINATION
ON
MASTER
SLAVE
GND
IN
GND
A
GND
B
GND
C
GND
D
GND
OUT
OFF
TERMINATION
ON
GND
Camera control terminal
Termination switch: OFF
Termination switch: ON
Shielded twisted-pair cable
Ch 1
Termination switch
ON
Ch 2
Termination switch
ON
Ch 3
Termination switch
ON
Ch 4
Termination switch
ON
Ch 5
Termination switch
ON
Ch 6
Termination switch
ON
Ch 7
Termination switch
ON
Ch 8
Termination switch
ON
[Connection cables]
• Recommended cable type: CPEV-S type (shielded twisted-pair cable) thicker than 0.65 mm in diameter.
• The maximum cable distance between the Combination camera and each Slave Connection terminal is 1.2 km.
[Termination switch setting]
• Set the termination switches of all connected cameras to ON.
• Make sure that the unit's termination switch is set as follows.
Units other than the last connected unit: Termination switch OFF
Last connected unit:
Termination switch ON