beautypg.com

Connecting 32 or more combination cameras, A + b + c 1.2 km – Toa C-IF500 User Manual

Page 6

background image

6

5.2. Connecting 32 or More Combination Cameras

Connect the Combination camera's control cable to the unit's Slave Connection Terminal, making sure to
match their polarities.

[Connection cables]

• Recommended cable type: CPEV-S type (shielded twisted-pair cable) thicker than 0.65 mm in diameter.
• If multiple cameras are connected to a single terminal, the total of each cable distance between connected

equipment must be 1.2 km or less.

[Termination switch setting]

• Set the unit's termination switch to ON when the unit and the C-RM500 Remote Controller are connected in

a matched pair in the system.

• Make sure that the termination switches of the cameras connected to the system are set as follows.

Cameras other than the last connected camera: Termination switch OFF
Last connected camera:

Termination switch ON

Interface unit

C-IF500

Combination

camera

Combination

camera

Combination

camera

a

b

c

a + b + c 1.2 km

<

Interface unit

C-IF500

Combination

camera

Combination

camera

Combination

camera

Terminal switch

OFF

Terminal switch

OFF

Terminal switch

ON

Caution
Up to 31 C-CC501, C-CC504, C-CC551, or
C-CC554 Combination Camera can be
connected to each Slave Terminal A-D.

Remote controller
C-RM500

C-IF500

Combination

camera

Combination

camera

MASTER

SLAVE

GND

IN

GND

A

GND

B

GND

C

GND

D

GND

OUT

OFF

TERMINATION

ON

GND

Camera control terminal

Ch 1

Termination switch

OFF

Ch 2

Termination switch

OFF

Ch 31

Termination switch

ON

Ch 32

Termination switch

OFF

Ch 33

Termination switch

OFF

Ch 62

Termination switch

ON

Termination switch: ON

Shielded twisted-pair cable